background image

 ARIES/ARIES-P 

- Ver. 04 

 23

D811184A_04

Fig. 3

COLLEGAMENTO CONDENSATORI IN CENTRALINA- CONNECTIONS TO THE TERMINALBOARD FOR THE CAPACITOR

CONNECTION DES CONDENSATEURS DANS LACENTRALE - KONDENSATOREN VERBINDUNG IN DER STEURUNG

CONEXION DELLOS CONDENSADORES EN LACENTRALDE MANDO - LIGA‚ÍE CONDENSADORES NACENTRALDE MANDO

JP12

JP4

TW

TCA

DL1

66

55

44

TDELAY

MOT1

MOT2

JP13

M1

M2

(r)

JP14

JP15

5
6
7

23

22

21

20

19

26

25

II¡

CH

18

17

16

15

14

13

JP

4

11 12

10

9

8

7

6

5

JP

3

JP

11

JP

6

JP

7

2

T

0,5

A

23

0V

T

1A

11

0V

T

2,5

A

23

0V

T

5A

11

0V

1

JP

5

JP

13

JP

12

JP

9

JP14

JP15

L

0V

0

12

12

T2

T3

T4

N

22

11

33

JP

8

JP

10

JP2

55

P

8
9

10

11

12

ON

12

34

5

6

DIP

M2

M1

JP1

5

JP1

4

JP1

3

JP1

2

Содержание ARIES

Страница 1: ...ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO CENTRALINA DI COMANDO D811184A ver 04 08 02 02 I CONTROL UNIT GB UNITÉ DE COMMANDE F STEUERZENTRALE D CENTRAL DE MANDO E CENTRAL DO MANDO P ARIES ARIES P 8 027908 113740 ...

Страница 2: ...ARIES ARIES P Ver 04 3 D811184A_04 ...

Страница 3: ...tocells only activated during closing OFF Photocells activated during opening and closing Automatic closing time TCA ON Automatic closing activated can be adjusted from 0 to 90s Preallarm mod ARIES P only ON The flashing light turns on abt 3 seconds before the motors start FOR THE INSTALLER check the boxes you are interested in START four step logic Gate closed Gate open During opening During clos...

Страница 4: ...ontrol devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed 3 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Absorption on empty 0 5A...

Страница 5: ... sockets as described below Pos T1 1st TORQUE MINIMUM TORQUE Pos T2 2nd TORQUE Pos T3 3rd TORQUE Pos T4 4th TORQUE MAXIMUM TORQUE 4 motor torque values can be obtained To gain access to the torque adjustment sockets disconnect the mains supply and remove the protective case P of the transfomer CAUTION Excessive torque adjustment may jeopardise the anti squash safety function On the other hand insu...

Страница 6: ... JP4 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MAX40W JP4 JP2 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 7 8 9 10 11 12 COMM START STOP PHOT NO NO NO II CH NC NC 0V SCA 24Vac COMM ANTEN 13 14 15 16 17 18 19 20 21 22 23 25 26 JP2 NO II CH 25 26 COMM START STOP PHOT NO NC NC 0V SCA 24Vac COMM PED ANTEN ...

Страница 7: ...LOS CONDENSADORES EN LA CENTRAL DE MANDO LIGA ÍE CONDENSADORES NA CENTRAL DE MANDO JP12 JP4 TW TCA DL1 66 55 44 TDELAY MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 23 22 21 20 19 26 25 II CH 18 17 16 15 14 13 JP4 11 12 10 9 8 7 6 5 JP3 JP11 JP6 JP7 2 T 0 5A 230V T 1A 110V T 2 5A 230V T 5A 110V 1 JP5 JP13 JP12 JP9 JP14 JP15 L 0V 0 12 12 T2 T3 T4 N 22 11 33 JP8 JP10 JP2 55 P 8 9 10 11 12 ON 1 2 3 4 5 6 DI...