2.10
BALANCED FLUE UTILISING EXISTING CHIMNEY (CONTINUED)
2.10.1
Check the soundness of the chimney to ensure that there are no leaks
or remedial work required. Sweep the chimney if necessary.
2.10.2
Feed the 4” / 100mm flue liner through the chimney.
2.10.3
Attach the sliding adaptor to the bottom of the flexible liner and secure
with the 2 off screws provided. (See figure 15 on previous page)
2.10.4
At the top of the chimney, attach the outside mounting plate with a hose
clip to the flexible liner and secure with 2 off screws. (See figure 15 on
previous page).
2.10.5
Fasten the outside mounting plate securely with stainless steel screws
and weatherproof as necessary.
2.10.6
Fix the terminal in position with a locking band and 3 off bolts. The
sliding adaptor should now protrude 100mm below the bottom of the
chimney opening. (See figure 15 on previous page).
2.10.7
Attach the internal mounting plate to the bottom part of the chimney and
seal with suitable high temperature sealant.
2.10.8
Install the Da Vinci or Distinction product and fit with a minimum 250mm
(preferably 500mm if space above the product allows) rigid section of
Metaloterm concentric flue (as supplied with the existing chimney flue
kit by the manufacturer).
2.10.9
Finally tighten the locking band of the internal mounting plate. (See
figure 15 on previous page).
2.10.10 Refer to section 3.3 to fit the correct restrictor plate to the fire. Fitting of
the correct restrictor plate is mandatory otherwise performance issues
with the product will be found.
NOTE : The concentric flue must extend a minimum of 100mm into the existing
chimney (past the internal mounting plate and please ensure all joints
are taped with suitable high temperature tape when assembling the flue
pipe sections together.