![background image](http://html1.mh-extra.com/html/bewell-connect/myscale-analyzer-bw-sc2w/myscale-analyzer-bw-sc2w_manual_2745227039.webp)
BewellConnect - BW-SC2 W / BW-SC3 W / BW-SC4 W / BW-SC6 W - User Manual - 082017
BewellConnect - BW-SC2 W / BW-SC3 W / BW-SC4 W / BW-SC6 W - User Manual - 082017
76
77
Guidance and manufacturer’s declaration - electromagnetic emissions.
The
BW-SC2W
and
BW-SC6W
are intended for use in an electromagnetic environment specified below. The custom-
er or the user of the
BW-SC2W
and
BW-SC6W
should ensure that it is used such an environment.
Emissions test
Compliance
Electromagnetic environment - guidance
RF emissions
CISPR 11
Group 1
The
BW-SC2W
and
BW-SC6W
use RF energy only
for their internal function. Therefore, their RF
emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
RF emissions
CISPR 11
Class B
-
The
BW-SC2W
and
BW-SC6W
are suitable for
use in all establishments, including domestics
and those directly connected to the public
low-voltage power supply network that supplies
buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class A
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Complies
Recommended separation distances between portable and mobile RF communications equipment
and the BW-SC2W and BW-SC6W.
The
BW-SC2W
and
BW-SC6W
are intended for use in an electromagnet-
ic environment in which radiated RF disturbances are controlled. The customer or the user of the
BW-SC2W
and
BW-SC6W
can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the
BW-SC2W
and
BW-SC6W
as
recommended below, according to the maximum output power of the communications equipment.
Rated maximum output
of transmitter
w
Separation distance according to
frequency of transmitter m
150 MHz to 80 MHz
[ 3.5
V
1
P
]√
d =
80 MHz to 800 MHz
[ 3.5
V
1
P
]√
d =
800 MHz to 2.5 GHz
[ 7
E
1
P
]√
d =
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rates at a maximum output power not listed above, the recommended separation distance d
in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is
the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800MHz, the reparation distance for the higher frequency range applies.
NOTE 2 these guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
W
ARR
ANT
Y
Содержание MyScale Analyzer BW-SC2W
Страница 3: ...BewellConnect BW SC2W BW SC3W BW SC4W BW SC6W User Manual 082017 5 FR MyScale BW SC2W SC3W SC4W SC6WW...
Страница 10: ...BewellConnect BW SC2W BW SC3W BW SC4W BW SC6W User Manual 082017 19 EN MyScale BW SC2W SC3W SC4W SC6W...
Страница 23: ...BewellConnect BW SC2W BW SC3W BW SC4W BW SC6W User Manual 082017 45 ES MyScale BW SC2W SC3W SC4W SC6W...
Страница 30: ...BewellConnect BW SC2W BW SC3W BW SC4W BW SC6W User Manual 082017 59 DE MyScale BW SC2W SC3W SC4W SC6W...