Programming overview

Function

Step 1

Step

2

Step 3

Step 4

Step 5

Change Password

Set card reader to

programming

mode

Press A27

Enter a new

password

Enter the

password again

Log on cards(with

the card)

Set card reader to

programming

mode

Press A01

Swipe the

card

Swipe the next

card, as

required

Press B to

revert to

programming

mode

Log on cards

(without the card)

Set card reader to

programming

mode

Press A03

Enter the card

number

Enter the next

card number, as

required

Press B to

revert to

programming

mode

Log on a series of

cards

Set card reader to

programming

mode

Press A04

Enter the first
number in the

series

Enter the last

number in the

series

Cancel cards (with

card)

Set card reader to

programming

mode

Press A14

Swipe the

card

Swipe the next

card, as

required

Press B to

revert to

programming

mode

Cancel cards

(without card)

Set card reader to

programming

mode

Press A16

Enter the card

number

Enter the next

card number, as

required

Press B to

revert to

programming

mode

Programme/change

common code

Set card reader to

programming

mode

Press A21

Enter the

common code

(4 digits)

Change door opening

time

Set card reader to

programming

mode

Press A28

Enter the

door open

time (01-99)

Buzzer on/off

Set card reader to

programming

mode

Press A65

0 = Off

1 = On

Erase memory and
set default settings

Set card reader to

programming

mode

Open the

reader

Press SW1 on

the circuit

board

Enter 112186

Enter 112186

again

Change card reading

parameters

Set card reader to

programming

mode

Press A97

Enter the start

position

Enter the

number of digits

to be read

Door operation on

toggle function

change

Set card reader to

programming

mode

Press A96

Содержание Bewacard BC610

Страница 1: ...Bewacard BC610 Installation and User manual GB...

Страница 2: ...ice 46 8 627 00 95 Reception Fax 46 8 627 00 96 Website www bewator se E mail support bewator se Bewator AB are parts of Bewator Group which develops and markets a complete security product range that...

Страница 3: ...on a card with a card 13 Log on a card without the card 13 Log on a series of cards 14 Cancel card with card 14 Cancel card without card 15 Program change erase the common code 15 Change the Door Ope...

Страница 4: ...at action is required to open the door The following security levels exist Unlocked door Common code A four digit code common to all users is required to open the door The common code is programmed by...

Страница 5: ...a suitable security level The Toggle function can be used in premises where a person is responsible during certain hours e g a class room or a loading bay door In a class room the teacher can open th...

Страница 6: ...rd reader with the key supplied The lock is located on the underside of the reader 2 Fasten the back plate against the wall using three screws according to the illustration below Seal the screw and ca...

Страница 7: ...to work properly so the voltage at the card reader should never be less than 21 V The recommended gauge cross sectional area of the conductor depends on the distance between the power supply and the c...

Страница 8: ...C610 Installation and User manual Installation 1 2 3 4 5 6 7 DURESS 0V CODE PIN TOGGLE READER INHIBIT EXIT BUTTON LOCK 12 30V 0V BACK LIGHT SW1 15 14 TAMPER TAMPER 1 2 3 4 5 6 7 8 9 10 11 8 9 10 11 12...

Страница 9: ...LED on the fascia will be lit 5 Duress output Used for activating an external alarm Use an E7 relay Connect between terminal nos 8 and 1 6 Remove the jumper if back lighting is not required 7 Control...

Страница 10: ...ull later Red LED Indicates errors E g cancellation of card following 3 incorrect PIN codes Yellow LED Indicates keypresses Lit when PIN code should be entered Green LED Lit when the door is unlocked...

Страница 11: ...and the LEDs In this manual the LEDs are illustrated in the following way Off Lit Flashes In programming mode before a function is chosen All three LEDs are flashing During programming The LEDs are li...

Страница 12: ...red 6 digit password on the card reader s keypad The password is now set Set the card reader to programming mode To program a function the card reader has to be in programming mode Proceed as follows...

Страница 13: ...ired 5 When finished press B to go back to programming mode 6 Press B one more time to leave programming mode Log on a card without the card Using this function cards can be programmed by keying in th...

Страница 14: ...rd number of the last card in the series The red LED flashes as the cards are logged on 5 Press B to leave programming mode Cancel card with card Using this function a card can be cancelled with the c...

Страница 15: ...al is heard 4 Cancel the next card as required 5 When finished press B to go back to programming mode 6 Press B one more time to leave programming mode Program change erase the common code This is how...

Страница 16: ...Enter the desired opening time between 01 and 99 seconds 4 Press B to leave programming mode Buzzer on off The default is that the buzzer is activated If you do not want the buzzer to beep on key pre...

Страница 17: ...ith the key supplied The lock is located on the underside of the card reader 3 Press the SW1 button see the wiring diagram on page 8 4 Press 112186 5 Press 112186 one more time All previously logged o...

Страница 18: ...A27 3 Enter the new password A warning tone is heard 4 Enter the new password again The warning tone sounds until all six digits have been entered 5 Press B to leave programming mode 6 Make a note of...

Страница 19: ...from which position on the magnetic strip the reader should start reading and how many digits should be read max 8 Note Previously logged on cards will not work if you change the card parameters 1 Set...

Страница 20: ...f this function This function can be changed so that the door remains unlocked when a security level changes This is setting 1 of the function To lock the door a valid transaction must be performed as...

Страница 21: ...mming mode Press A14 Swipe the card Swipe the next card as required Press B to revert to programming mode Cancel cards without card Set card reader to programming mode Press A16 Enter the card number...

Страница 22: ...22 BC610 Installation and User manual Name chart Common Code Name Card Number...

Страница 23: ...of the above mentioned ways depending on the current security level The door remains open until a user need not be the same one as opened the door again completes a valid transaction Note A door that...

Страница 24: ...card Duress To activate the Duress alarm output if forced to open the door under threat this works during the Card PIN security level only 1 Swipe the card through the card reader and enter the usual...

Страница 25: ...erminal block nos 1 and 4 in the card reader is missing Check cable between card reader and lock Change locks Attach jumper A card is swiped through the card reader but nothing happens No beep is hear...

Страница 26: ...0 mA Lock relay Max 2A 30 V DC Duress output Open collector to 0 volt Max 500 mA 30 V DC Tamper switch Max 1A 30 V DC Inputs Normally pulled high Active when they are pulled low i e 0 V Temperature ra...

Страница 27: ...______________________ _________________________________________________ _________________________________________________ _________________________________________________ ___________________________...

Страница 28: ......

Отзывы: