10

BC610 Installation and User manual

Layout of the keypad

Diagram of the LEDs and push-buttons on the BC610 keypad.

 

1

2

3

4

5

6

7

8

9

A

0

B

All LEDs are flashing in programming mode. The LEDs also
have other indications explained in full later.

Red LED.

Indicates errors. E.g.
cancellation of card
following 3 incorrect
PIN codes.

Yellow LED.

Indicates keypresses. Lit when PIN
code should be entered.

Green LED.

Lit when the door is unlocked.
E.g. Accepted card transaction

A.

Initiates program-
ming sequence,
e.g A01 to log on
cards. Also used
when choosing
PIN code
(see page 24).

B.

Press B + the 6-digit password
whenever you want to program
BC610. Press B to leave
programming mode.

Содержание Bewacard BC610

Страница 1: ...Bewacard BC610 Installation and User manual GB...

Страница 2: ...ice 46 8 627 00 95 Reception Fax 46 8 627 00 96 Website www bewator se E mail support bewator se Bewator AB are parts of Bewator Group which develops and markets a complete security product range that...

Страница 3: ...on a card with a card 13 Log on a card without the card 13 Log on a series of cards 14 Cancel card with card 14 Cancel card without card 15 Program change erase the common code 15 Change the Door Ope...

Страница 4: ...at action is required to open the door The following security levels exist Unlocked door Common code A four digit code common to all users is required to open the door The common code is programmed by...

Страница 5: ...a suitable security level The Toggle function can be used in premises where a person is responsible during certain hours e g a class room or a loading bay door In a class room the teacher can open th...

Страница 6: ...rd reader with the key supplied The lock is located on the underside of the reader 2 Fasten the back plate against the wall using three screws according to the illustration below Seal the screw and ca...

Страница 7: ...to work properly so the voltage at the card reader should never be less than 21 V The recommended gauge cross sectional area of the conductor depends on the distance between the power supply and the c...

Страница 8: ...C610 Installation and User manual Installation 1 2 3 4 5 6 7 DURESS 0V CODE PIN TOGGLE READER INHIBIT EXIT BUTTON LOCK 12 30V 0V BACK LIGHT SW1 15 14 TAMPER TAMPER 1 2 3 4 5 6 7 8 9 10 11 8 9 10 11 12...

Страница 9: ...LED on the fascia will be lit 5 Duress output Used for activating an external alarm Use an E7 relay Connect between terminal nos 8 and 1 6 Remove the jumper if back lighting is not required 7 Control...

Страница 10: ...ull later Red LED Indicates errors E g cancellation of card following 3 incorrect PIN codes Yellow LED Indicates keypresses Lit when PIN code should be entered Green LED Lit when the door is unlocked...

Страница 11: ...and the LEDs In this manual the LEDs are illustrated in the following way Off Lit Flashes In programming mode before a function is chosen All three LEDs are flashing During programming The LEDs are li...

Страница 12: ...red 6 digit password on the card reader s keypad The password is now set Set the card reader to programming mode To program a function the card reader has to be in programming mode Proceed as follows...

Страница 13: ...ired 5 When finished press B to go back to programming mode 6 Press B one more time to leave programming mode Log on a card without the card Using this function cards can be programmed by keying in th...

Страница 14: ...rd number of the last card in the series The red LED flashes as the cards are logged on 5 Press B to leave programming mode Cancel card with card Using this function a card can be cancelled with the c...

Страница 15: ...al is heard 4 Cancel the next card as required 5 When finished press B to go back to programming mode 6 Press B one more time to leave programming mode Program change erase the common code This is how...

Страница 16: ...Enter the desired opening time between 01 and 99 seconds 4 Press B to leave programming mode Buzzer on off The default is that the buzzer is activated If you do not want the buzzer to beep on key pre...

Страница 17: ...ith the key supplied The lock is located on the underside of the card reader 3 Press the SW1 button see the wiring diagram on page 8 4 Press 112186 5 Press 112186 one more time All previously logged o...

Страница 18: ...A27 3 Enter the new password A warning tone is heard 4 Enter the new password again The warning tone sounds until all six digits have been entered 5 Press B to leave programming mode 6 Make a note of...

Страница 19: ...from which position on the magnetic strip the reader should start reading and how many digits should be read max 8 Note Previously logged on cards will not work if you change the card parameters 1 Set...

Страница 20: ...f this function This function can be changed so that the door remains unlocked when a security level changes This is setting 1 of the function To lock the door a valid transaction must be performed as...

Страница 21: ...mming mode Press A14 Swipe the card Swipe the next card as required Press B to revert to programming mode Cancel cards without card Set card reader to programming mode Press A16 Enter the card number...

Страница 22: ...22 BC610 Installation and User manual Name chart Common Code Name Card Number...

Страница 23: ...of the above mentioned ways depending on the current security level The door remains open until a user need not be the same one as opened the door again completes a valid transaction Note A door that...

Страница 24: ...card Duress To activate the Duress alarm output if forced to open the door under threat this works during the Card PIN security level only 1 Swipe the card through the card reader and enter the usual...

Страница 25: ...erminal block nos 1 and 4 in the card reader is missing Check cable between card reader and lock Change locks Attach jumper A card is swiped through the card reader but nothing happens No beep is hear...

Страница 26: ...0 mA Lock relay Max 2A 30 V DC Duress output Open collector to 0 volt Max 500 mA 30 V DC Tamper switch Max 1A 30 V DC Inputs Normally pulled high Active when they are pulled low i e 0 V Temperature ra...

Страница 27: ...______________________ _________________________________________________ _________________________________________________ _________________________________________________ ___________________________...

Страница 28: ......

Отзывы: