EMC 

This monitor conforms to European Standard EN 61326 and is subject to particular pre-
cautions  with  regard  to  electromagnetic  compatibility  (EMC).  Please  note  that  portable 
and  mobile  HF  communication  systems  may  interfere  with  this  instrument.  For  more 
details, please contact customer service at the address indicated. 
 

Function of the test strips 

The test strips provide a quantitative measurement of the glucose content of the capillary 
whole blood. When the slot for blood taking comes into contact with a drop of blood, it is 
automatically filled by simple capillary action. The blood is drawn into the absorption slot 
in the test strip and the monitor measures the glucose content of the blood.  
The  test  is  based  on  the  measurement  of  an  electric  current  that  is  generated  by  the 
chemical reaction of the glucose with the reagent on the strip. The monitor analyses the 
current. The current depends on the glucose content of the blood sample. The results are 
shown on the display of the blood glucose monitor. Only a very small volume of blood is 
required  (0.5  microlitre)  and  the  actual  measurement  takes  about  six  seconds.  The  test 
strips can measure glucose values from 20 to 600 mg/dL. 
 

Chemical constituents of the test strip sensor 

  Glucose oxidase 10% 

  Electron shuttle 50% 

  Enzyme protection 8% 

  Non-reactive constituents 32% 

 

Function of the control solution 

The control solution contains a specific proportion of glucose, which reacts with the test 
strip. A test with control solution is similar to a blood test. The difference is that a drop of 
control solution is used instead of a drop of blood. The test result with the control solution 
must be within the result range. The result range is printed on every test strip container.  
 

Chemical composition of the control solution 

The control solution is a red solution with a D-glucose content of less than 0.2%. 
 
Ingredients 

 

 

Percentage 

D-glucose 

 

 

0.05 – 0.19% 

Salts 

 

 

 

1.4% 

Substance for regulating viscosity 

15.0% 

 
Controls 

The 

Beurer GL30 mg/dL blood glucose monitoring system

 for self-testing conforms to  

the  following  European  Directives  and  standards:  IVD  (98/79/EC),  EN 61010-1,  
EN 61010-2-101, EN 13640, EN ISO 14971, EN ISO 15197, MDD (93/42/EC).  

Содержание GL30 mg/dL

Страница 1: ...BLOOD GLUCOSE MONITORING SYSTEM Step by step instructions for use GL30 GB Beurer GmbH S flinger Stra e 218 89077 Ulm Germany www beurer medical com...

Страница 2: ......

Страница 3: ...or 8 3 3 Test strips 11 4 Operation and Basic Settings 13 4 1 Inserting and replacing batteries 13 4 2 Making basic settings 13 4 3 Checking code number coding 14 5 The measurement 15 5 1 Taking a blo...

Страница 4: ...itor GL30 mg dL REF 162 544 B 10 test strips REF 162 511 C 1 lancing device with AST cap for taking blood samples at different parts of the body REF 162 501 D 10 sterile lancets REF 162 513 E 1 handy...

Страница 5: ...date and time setting the temperature unit C or F coding the monitor The monitor also permits the following control functions display of the ambient temperature and warning of unsuitable temperatures...

Страница 6: ...countries Not for reuse single use only Green Dot German dual waste disposal system Use by Contents sufficient for n tests Maximum storage period in months after opening Art Nr Order number Batch Ster...

Страница 7: ...rposes they are not a substitute for a medical examination Discuss your readings with a doctor regularly Never change your doctor s instructions without dis cussing your changes with the doctor Accura...

Страница 8: ...ritation if inhaled or swallowed Keep the container away from small children Batteries saving readings WARNING Batteries can be fatal if swallowed You should store the batteries out of reach of small...

Страница 9: ...ly to prevent injury and infection of other persons Dispose of test strips and lancets in a sharps container after use Note Used completely discharged batteries must be disposed of in specially marked...

Страница 10: ...lancets 1 2 3 4 5 6 1 Cap 2 Safety shield of lancet 3 Sterile lancet 4 Lancet holder 5 Trigger button 6 Trigger setting mechanism 3 2 Blood glucose monitor Front Back 1 Slot for test strips 2 LCD dis...

Страница 11: ...est strips 3 Results display 4 Low blood glucose low 5 High blood glucose high 6 Test strip symbol 7 Speaker non functional 8 Blood drop symbol 6 9 Blood glucose unit mg dL 10 Blood glucose unit mmol...

Страница 12: ...ay 16 Time hour minute 17 Replace battery symbol 18 CTL for control solution 19 DAY AVG for average reading 7 14 21 28 60 90 days 20 AM morning 21 PM afternoon Note The blood glucose monitor is suppli...

Страница 13: ...trip into the unit with the contacts first Make sure that the front of the test strip is facing you Read carefully the following information on the handling and storage of your test strips All instruc...

Страница 14: ...onths on the la bel The storage time is reduced if it extends beyond the use by date see date beside the hourglass icon Do not use the test strips if one of the use by dates has expired The test strip...

Страница 15: ...t takes longer than usual see 4 2 Making basic settings page 13 3 Insert two new AAA 1 5 V alkaline batteries Make absolutely sure that you insert them with the correct polarity as marked Do not use r...

Страница 16: ...ayed and the Memory symbol starts blinking Caution all previously stored results will be deleted if you press M now Press the SET button OFF is displayed briefly and the moni tor automatically switche...

Страница 17: ...od sample Preparing to take the blood sample 1 Select part of body for blood sample You can take blood samples with the lancing device from the fingerprints or other parts of the body such as palm of...

Страница 18: ...e other hand Repeated puncture wounds at one puncture site may cause inflammation loss of feeling or scarring Do not use the AST cap for taking a blood sample from the finger Never compress the finger...

Страница 19: ...at the blood remains in drop form and is not smeared Blood sample from the fingerprint Position the lancing device firmly and slightly off centre on the fingerprint Press the trigger button Remove the...

Страница 20: ...contact with them This will pre vent injury and infection of other people 12 Screw the cap grey on again 5 2 Measuring blood glucose 1 Hold the monitor with the display facing you 2 Insert a test stri...

Страница 21: ...age 25 7 Remove the test strip from the monitor Dispose of the test strip as directed to prevent infection of other persons Note Do not apply more blood if the monitor does not start the measurement R...

Страница 22: ...g dL Regular self monitoring high 121 mg dL and above If this value still remains high two hours after your last meal it may indicate hyperglycaemia high blood sugar Talk to your doctor about any requ...

Страница 23: ...atically and shows consecutively the initial display the ambient temperature and the code number The monitor is ready for a test as soon as the flashing blood drop symbol 6 is displayed 4 Check the co...

Страница 24: ...You did not dispose of the first drop of control solution The top of the vial was not wiped clean The vial was not shaken sufficiently Correct the cause and repeat the test Control solution has expire...

Страница 25: ...lues You can display the average values of your blood glucose readings for the last 7 14 21 28 60 and 90 days At the same time the monitor shows how frequently you have con ducted tests over this peri...

Страница 26: ...seconds The display briefly reads OFF 5 The monitor switches off automatically 6 2 Deleting stored values 1 The monitor must be switched off Remove the battery cover from the back of the monitor 2 Pr...

Страница 27: ...d protect it against any impact You should protect the monitor from moisture dirt dust blood control solution or water major temperature fluctuations and direct sunlight Do not use the monitor in the...

Страница 28: ...es not start after inserting the test strip into the monitor and applying the blood Cause Remedy Blood volume too low Repeat test with new test strip and greater volume of blood Faulty test strip Repe...

Страница 29: ...ys Automatic shutoff Three minutes after last activity Storage and transport temperature Temperature 4 C 40 C Relative humidity 10 85 Operating ranges Temperature 10 C 40 C Relative humidity 10 85 non...

Страница 30: ...lay of the blood glucose monitor Only a very small volume of blood is required 0 5 microlitre and the actual measurement takes about six seconds The test strips can measure glucose values from 20 to 6...

Страница 31: ...ntion This guarantee does not affect your statutory rights In order to make a claim within the warranty period the customer is required to provide proof of purchase Claims must be made within a period...

Страница 32: ...GL30_mg dL_0309_GB Subject to error and change...

Отзывы: