ASSEMBLY OF HANDPIECE (CONTINUED)
Blade Installation (Continued)
•
Adjust the housing for proper running clearance. The blade should turn freely with a slight
side-to-side motion. This leaves room for the grease
WARNING!
Make certain that the blade is free to rotate in the housing. If the blade does not
turn freely, it may cause the tool to rotate in the hand.
•
Tighten the left cover screw to 35 in-lb. (4 N-m). Use of the Bettcher torque wrench kit is
recommended.
•
Re-check the running clearance.
Blade is too tight
•
If the blade is too tight in the housing, adjustments can be made by loosening the left cover
retaining screw and slightly spreading open the housing.
•
Check the housing for proper running clearance and retighten the left cover screw to 35
in-lb. (4 N-m). Use of the Bettcher
®
torque wrench kit is recommended.