Page 61
9.4.11
Drive Link Removal (Continued)
Use a small screwdriver to remove the clevis screw. Turn the AirShirz
®
over and use a small
diameter rod or a paper clip to push or tap the clevis pin out. Move the power cylinder rod
outward slightly and push aside the tubing as needed to gain access to the end of the clevis pin.
Pull outward on the power cylinder if necessary to let the pin clear the frame.
Pivot the power cylinder outward being careful not to bend the swivel fitting at the rear of the
cylinder. Grasp the drive link at the clevis end. Pull outward while tipping upward to let the drive
pin slide out of the slot in the servo linkage, as shown below.
FIGURE #59
Do Not Stress
Rear Fitting