Status LED

LED green  The device is connected to the power supply. The consumer is supplied with mains  

 

 

power and the internal battery is charging.

LED yelllow  The power supply is interrupted. The consumer is supplied with power from the  

  internal 

battery. 

LED red 

The power supply is interrupted and the charge level of the internal battery is low.  

  In this case, the UPS cannot supply the connected load with power for much longer.

Intended use

The SmartUPS serves exclusively for the power supply of electrical devices with 12V 5A in the 

private and commercial sector, the intendet use of which does not prohibit this.

It is to be used exclusively in dry interior rooms, in which the ambient temperature does not ex-

ceed 50 °C.

The input current (INPUT) of your device may not excess the maximum output (OUTPUT) of this 

product!

The intended use also includes compliance with all information specified in this manual. Any use 

otherthan the intended use is considered incorrect use.

Connecting and Operating

Setup

1. Compare the technical data of all devices used and ensure their compatibility.
2. Connect your 12V device to the output connector of the UPS.
3. Connect the SmartUPS to a 230V socket using the power supply unit supplied. The UPS  

switches on automatically and supplies the output with power. The status LED lights green  

and the internal battery is charging.

4. To switch off the device, take the device off the mains and press the red button on the side for 

about 1 second. The UPS will shut down until the next time you connect it to power. Disconnect 

all cable connections after usage.

Operating 

Interrupted power supply

 

If the input voltage is disconnected or if there is a power failure, the UPS switches to battery 

operation so that the connected load continues to be supplied with power. The LED flashes yel

-

low and the battery discharges over time. When switching to battery operation, you will receive a 

notification via SMS.

Low battery charge level

When the battery is low, the LED lights up red. In this case, the UPS cannot supply the connected 

load with power for much longer. You will receive a new notification via SMS, informing you that 

the battery is soon empty.

Returning power supply

When the UPS is plugged in again or the power returns, the LED will turn green again and the 

UPS will start charging the battery while the load is powered from the mains. You will receive a 

notification via SMS that the mains voltage has been restored.

Telephone number setup for receiving notifications

1. 

Check the UPS identification plate for the telephone number and serial number of the UPS 

(Example see Fig. 2 Identification plate).

2.  Connect the UPS to power (the Status LED lights up green).
3. Wait 20 - 30 seconds after switching on.
4. Send an SMS with the 7-digit serial number from the telephone number with which you want  

to receive the notifications to the telephone number on the identification plate.

5. 

You will receive a notification via SMS for confirmation.

Note: Locking of SIM card

 

Please avoid frequent plugging and unplugging of the UPS to prevent the SIM card in the 

device from being locked if too many notifications are being sent. If your SIM card is being 

blocked nevertheless, please have the serial number and phone number of the device at 

hand and contact: 
Bürger Electronic GmbH, Auf dem Graben 21, 71111 Waldenbuch, Germany 

Phone: +49 7157/734860

Use of SIM card 

We hereby explicitly prohibit the use of the SIM card, or the telephone number, for other 

purposes. If this is not complied with, the SIM card will be permanently locked.

Maintenance

The SmartUPS should be connected to the mains supply for 2-3 hours at least once every 3 

months in order not to unnecessarily strain the life of the internal batteries and to prevent them 

from being damaged, for example by deep discharge.

Содержание SmartUSV

Страница 1: ...BEDIENUNGSANLEITUNG USER MANUAL DE EN SmartUSV V01 08 2020 ...

Страница 2: ...e sowie die Verwertung und oder Mitteilung des Inhaltes sind ohne schriftliche Genehmigung der Bürger Electronic GmbH im Folgenden Hersteller außer für interne Zwecke nicht gestattet Zuwiderhandlungen verpflichten zu Schadenersatz Der Hersteller behält sich das Recht vor zusätzliche Ansprüche geltend zu machen DE Sicherheitshinweise ACHTUNG Beim Öffnen von Abdeckungen oder Entfernen von Teilen auß...

Страница 3: ...m privaten und gewerblichen Bereich deren bestimmungsgemäße Verwendung dies nicht unter sagt Sie ist ausschließlich in trockenen Innnenräumen zu verwenden in denen die Umgebungs temperatur 50 C nicht übersteigt Der Eingangsstrom INPUT Ihres Gerätes darf die max Belastbarkeit OUTPUT dieses Produktes nicht überschreiten Zur bestimmungsgemäßen Verwendung gehört auch die Einhaltung aller Angaben in di...

Страница 4: ...igung per SMS Hinweis Sperrung der SIM Karte Bitte vermeiden Sie häufiges Ein und Ausstecken der USV um zu verhindern dass die SIM Karte im Gerät bei zu häufigen Benachrichtigungen gesperrt wird Sollte Ihre SIM Karte dennoch gesperrt werden halten Sie bitte die Seriennummer und die Telefonnummer des Gerätes parat und wenden Sie sich an Bürger Electronic GmbH Auf dem Graben 21 71111 Waldenbuch Tele...

Страница 5: ...mmencing any work The basic prerequisite for working safely is compliance with all safety instructions and usage instructions specified in this manual Furthermore the local accident prevention regulations and the general safety regulations in the area in which the device is operated apply Copyright This manual is copyright protected Handover of this manual to third parties reproductions of any typ...

Страница 6: ...Weight 4 Ah Version approx 5 kg 8 Ah Version approx 8 kg Dimensions W x L x H 4 Ah Version 24 x 32 x 9 cm 8 Ah Version 40 x 36 x 16 cm Connection Safety plug 230V Overview battery life Load capacity consumer Capacity UPS 4 Ah Capacity UPS 8 Ah Capacity UPS 16 Ah 5 W 10 hours 20 hours 40 hours 10 W 5 hours 10 hours 20 hours 20 W 2 5 hours 5 hours 10 hours 25 W 8 hours Description of function The un...

Страница 7: ...The LED flashes yel low and the battery discharges over time When switching to battery operation you will receive a notification via SMS Low battery charge level When the battery is low the LED lights up red In this case the UPS cannot supply the connected load with power for much longer You will receive a new notification via SMS informing you that the battery is soon empty Returning power supply...

Страница 8: ...ce with the European Directive 2002 96 EC on waste of electrical and electro nic equipment The directive provides the framework for an EU wide take back and recycling of old de vices To return your old device please use the return and collection systems available to you Battery Pb battery contains lead ...

Страница 9: ...Bürger Electronic GmbH Auf dem Graben 21 71111 Waldenbuch 49 7157 73486 0 info beteso com www beteso com ...

Отзывы: