betamotor.com
3
ENGLISH
Maintenance and checks
66
IGNITION GENERATOR CHECK
To check that the current generator is
operating correctly, proceed as follows:
The check in question must be perfor-
med while the temperature of the com-
ponent is approximately 20°C.
The check may also be performed with
the generator mounted on the motorbike
or on the engine.
Disconnect the black, 12-way connector
between the generator and the CDI.
Disconnect the white, 2-way connector
between the generator and the wiring.
Use a multimeter to check that the resi-
stances read between the terminals
shown below fall within the prescribed
range:
BLACK-WHITE
320 ohm ±15%
(Pick-Up)
RED-BLUE
15 ohm ±15 %
(condenser charging)
YELLOW-YELLOW 0.6 ohm ±30%
(service power supply)