background image

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Manual

Reflow-Controller

Page 2 of 14

2.  Safety Information 

2.1. 

Intended use 

This product may only be used in the control of a Reflow Oven. 

Any usage of this product other than that described above is likely to lead to 

damage including short-circuiting, fire, electric shocks etc. It is forbidden to alter 

and/or convert the entire product in any way. 

This product fulfills the legal, national and European requirements. All company 

names and product designs are registered trademarks of the respective owners. 

All rights reserved. 

Acquaint yourself with the operating instructions of the CONTROLLER, which you 

will find on the CD supplied with the Reflow oven. 

 

2.2. 

Safety Instructions 

Any damage caused by neglect of the operating instructions renders any 

guarantee/warranty null and void! We accept no liability for any damages so 

caused! 

We accept no liability for any special or personal injuries caused by inappropriate 

handling or neglect of the safety instructions. In such cases the 

warranty/guarantee is null and void. 

• 

For safety and copyright (EU) reasons no arbitrary changes or alterations to 

the product are permitted. Never disassemble the unit! 

• 

The product is designed for operation through the mains supply only 

(230V~/50Hz). Must be properly earthed. Connect the CONTROLLER to a 

socket using the supplied protected plug only. 

• 

This product is not a toy and is not intended for use by children. Operate the 

product out of the reach of children, same goes for storage. Children may 

attempt to insert items into the openings on the unit, risking a lethal electric 

shock! 

• 

The product is suitable for dry conditions only, do not allow it to become damp 

or wet. Never operate the product outdoors or in humid conditions, never 

touch it with damp or wet hands! Danger of lethal electric shock! 

• 

The product should not be operated unsupervised. 

Содержание Reflow

Страница 1: ......

Страница 2: ...Safety Instructions 2 3 Introduction 4 4 Overview 5 5 Technical Data 5 6 Command buttons 5 7 Operation 6 7 1 Soldering procedure 6 7 2 Learning Mode 7 7 3 System Self test 8 7 4 Temperature calibrati...

Страница 3: ...ct to copyright and may not be reproduced or made accessible to a third party in part or in whole without the written consent of the authors 1 1 Warranty and Liability In principle our general sales a...

Страница 4: ...for any damages so caused We accept no liability for any special or personal injuries caused by inappropriate handling or neglect of the safety instructions In such cases the warranty guarantee is nul...

Страница 5: ...the connection of the product to a PC it should be unplugged from the mains Handle the product with care impacts even by falls from a small height can damage it Cease using the unit if the housing of...

Страница 6: ...g phase Thus mechanical stresses in the board and in the components are avoided After the preliminary heating the temperature is increased to just under the soldering temperature This allows the volat...

Страница 7: ...rating voltage 230V 50Hz Max connected load 1500 W PC Connection RS232 Pin 2 TxD Pin 3 RxD Pin 5 GND 9600 Baud 8 bit NO parity 1 stop bit no handshake 6 Command buttons Off CONTROLLER switched off Plu...

Страница 8: ...e temperature sensor under or on the board in such a way that it touches it This is to ensure that the temperature sensor measures the board temperature and not the air temperature Close the oven door...

Страница 9: ...be selected For a successful learning mode you should place a board in the oven and the temperature sensor under or on the board so that it is touching it Thereby ensuring that the temperature sensor...

Страница 10: ...ation The temperature sensor of the Reflow CONTROLLER is preset and does not have not to be calibrated normally However if necessary the Reflow CONTROLLER can be adjusted to the sensor The temperature...

Страница 11: ...PC 7 6 Settings Adjust the serial interface of the attached computer to the following parameters 9600 Baud 8 bit NO parity 1 stop bit no handshake After the switching on of the CONTROLLER it announces...

Страница 12: ...Current temperature will not be displayed Temperature will be displayed in the format seconds xxx degC e g 31 058 52 C Data is separated by a comma This data if stored on the operating system can late...

Страница 13: ...r ENTER indicates the current value phtpwr 80 ENTER the oven will heat to 80 of capacity soaktemp Temperature of soaking phase 0 to 254 degrees soaktemp ENTER indicates the current value soaktemp 165...

Страница 14: ...erature dwelltime Duration of the retaining phase 0 to 254 sec dwelltime ENTER indicates the current value dwelltime 40 ENTER adjusts duration to 40 seconds dwellpwr Capacity of the retaining phase 0...

Страница 15: ...ety fuses or bypassing of the safety fuse is not permitted Repairs are to be carried out exclusively by an authorized specialist Obsolete electronic devices are recyclable materials and do not belong...

Страница 16: ...the equipment including arbitrary alteration of the circuitry Unspecified construction improper storage of components incorrect wiring of components such as switch potentiometer sockets etc Use of for...

Отзывы: