12
Trouble shooting
If problems occur please check the procedures listed
below before calling a service agent. If the fault find-
ing procedures do not rectify the problem contact
your service agent. For contact details refer back
page 14 of this manual.
Important:
Only an authorised person from the Service Agent is
qualified to service gas and electric systems.
What’s wrong
Possible cause
Solution
If none of the electrical systems
work
♦
Power turned off.
♦
Faulty
fuse.
♦
The automatic safety switch
has been tripped or a fuse
has blown.
♦
Turn power on.
♦
Check the fuse in the main
fuse box and replace if
faulty.
♦
Check the main fuse to
whether the automatic trip
switch or a differential
switch has tripped.
The electronic ignition system
does not work.
♦
There may be food or clean-
ing product particles be-
tween the spark plugs and
the burners.
♦
The burners are wet.
♦
The burner caps are not
located correctly.
♦
Clean the gap between the
spark plug ad the burner.
♦
Dry the burner carefully.
♦
Make sure that the burner
caps are located correctly.
The flames on the burners are
not evenly distributed.
♦
The burner has not been
assembled correctly.
♦
The burner gas ports are
dirty.
♦
Assemble the burner com-
ponents correctly.
♦
Clean the burner gas ports.
The gas flow does not seem
normal or there is no gas flow at
all.
♦
The isolation valve is
closed.
♦
If gas is supplied from a gas
bottle, the bottle may be
empty.
♦
Open the isolation valve.
♦
Replace the gas bottle with
a full one.
You can smell gas.
♦
One of the gas taps has
been left open.
♦
Possible leak on the gas
bottle coupling.
♦
Check all the gas taps are
closed.
♦
Check that the gas coupling
on the bottles is in order.
If the safety shut off on a burner
does not work.
♦
The control knob was not
held down long enough.
♦
The burner ports are dirty.
♦
Hold the burner down a few
seconds longer on ignition.
♦
Clean the burner ports.
Flames are normally blue and sharply defined. If flames are yellowish or noisy, or if the gas does not ig-
nite within the period specified under ‘boiling burner operation’, abnormal operation is indicated. Call your
local Service Agent.