11
Conversion
Propane Gas to Natural Gas
1. Shut off gas supply to the appliance.
2. Remove each burner cap and burner skirt.
3. Remove the Propane Gas injector (A) with a 7
mm/VF tube spanner (B) and replace with the
appropriate size Natural Gas injector for each
burner. The injector sizes required for Natural
Gas conversion are listed on the table on previ-
ous page.
4. Disconnect gas inlet pipe from the LPG Gas test
point inlet fitting.
5. Remove the Propane Gas test point inlet fitting
from the appliance.
6. Fit the Natural Gas Regulator supplied in the
conversion kit.
7. Connect the gas supply to the regulator. (Check
the direction of the regulator gas flow).
8. Check for gas leaks. NEVER use a naked flame
to check for gas leaks.
9. Adjust the gas pressure to 1.00 kPa.
10. Remove the control knob. Using a thin shaft
blade screwdriver down the centre of each gas
valve shaft, screw the throttle anti-clockwise to
achieve a stable simmer position. Test the ap-
pliance on both high and low flame for each
burner. If the burner fails to remain alight or the
flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.
11. Remove the ‘Only for use with Propane Gas’
label and replace with ‘Only for use with Natu-
ral Gas’ label. Label supplied in the conversion
kit.
Natural Gas to Propane
1. Remove each burner cap and burner skirt.
2. Shut off gas supply to the appliance.
3. Remove each burner cap and burner skirt.
4. Remove the Natural Gas main injector with a
7 mm/VF tube spanner and replace with the
appropriate size Propane Gas main injector for
each burner. The injector sizes required for Pro-
pane Gas conversion are listed on the table on
previous page.
5. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas
valve spindle, screw the throttle fully down clock-
wise.
6. Disconnect gas inlet pipe from the Natural Gas
Regulator.
7. Remove the Natural Gas Regulator from the
appliance.
8. Fit the Propane Gas test point inlet fitting sup-
plied in the conversion kit.
9. Connect the gas supply to the inlet fitting.
10. Open gas supply to the appliance.
11. Check for gas leaks. NEVER use a naked flame
to check for gas leaks.
12. Adjust the gas pressure to 2.75 kPa.
13. Test the appliance on both high and low flame
for each burner and check the gas pressure. If
the burner fails to remain alight or the flame
is not stable on the simmer setting, adjust the
by-pass screw, until flame is stable.
14. Remove the ‘Only for use with Natural Gas’
label’ and replace with ‘Only for use with Pro-
pane Gas’ label. Label supplied in the conver-
sion kit.