10
Natural Gas connection
Natural Gas installations
require the connection of
a gas regulator at the ap-
pliance. The regulator
and transition fittings are
supplied with the unit. Fit
as indicated in the adja-
cent figure. The transition
piece on the supply side
of the regulator must be
provided by the installer.
Propane Gas connection
In a LPG installation gas
regulation is made at the
gas cylinder and no fur-
ther regulator is re-
quired.
Connect
the
supply to the unit as
shown in the adjacent
figure
Check for gas sound-
ness at connections.
NEVER use a naked
flame to check for leaks.
The supply connection point must be accessible with
the appliance installed.
Boiling burner adjustments
These burners have no aeration adjustment.
To adjust the turn-down (simmer) rate (Nat Gas
only):
♦
Turn the control knob to the ‘low flame’ position.
♦
Pull control knob (M) off the gas tap spindle.
♦
Insert a small screwdriver (D) into the hole down
the spindle (C) and turn the throttle screw to in-
crease or reduce flame height.
♦
Check that the flame is stable when the control
knob is moved quickly from ‘full on’ to ‘turn-
down’ position.
Note: Burners operating on LPG should not be ad-
justed. The throttle screw must be fully screwed
down.
Check correct operation of each burner individually
and in combination. Burner flames should be clear
blue, with no yellow tipping. If the burner shown any
abnormality, check that the burner heads are cor-
rectly located and refer to the ‘maintenance’ section
on page 14. If satisfactory performance cannot be
obtained, contact Bestlink International or the local
gas utility. For service contact number refer to back
page of the cut-out.
Energy consumption
Natural gas
Burner
NG injector
size (mm)
1 kPa
NG
MJ/hr
Double ring (wok)
burner
1.70
13.50
Rapid burner
1.40
10.50
Semi rapid burner
1.10
6.00
Auxiliary burner
0.90
3.50
LP gas
Burner
LP injector
size (mm)
2.75 kPa
LP
MJ/hr
Double ring (wok)
burner
0.98
12.50
Rapid burner
0.90
10.50
Semi rapid burner
0.70
6.00
Auxiliary burner
0.55
4.00
Electrical connection
The cooktop is fitted with a 1.8 m electric lead. A
10 amp socket must be within 1 m of the cooktop.
The socket must remain accessible after installation
of the unit.
Important note:
The power lead must be fixed to the kitchen unit to
prevent it coming into contact with hot parts of the
hob (or an oven installed underneath) and remain
accessible after installation of the cooktop.
The wiring diagram is attached to the underside of
the unit. A copy is also printed at the back of this
manual.
The appliance must be earthed.
Warranty warning
It should be noted that we can not accept any liability
for direct or indirect damage caused by wrong con-
nection or improper installation. When being re-
paired , the appliance must always be disconnected
from the main gas and electricity supply; if required
notify our customer service.