Service and Maintenance
3–22
Key Combinator Service Manual
.
4. While holding the depth adjuster in place, tighten the spanner nut.
If the depth adjuster moves while you are tightening the spanner
nut,
go to Step 5. Otherwise, go to Step 6.
5. If the depth adjuster moves while you are tightening the spanner
nut:
■
Loosen the spanner nut again.
■
Return the depth adjuster to its original position, using the lead or
grease mark as your reference.
■
Repeat Step 2 through Step 4.
6. Perform the following steps:
■
Cut the calibration key (
■
Place the key in the gauge (
■
Read the gauge (
■
Total and check the measurement (
Note:
The new keycut depth should be within calibration range. If
not, send the key combinator to the BEST factory for repair.
Figure 3.19
Turning the depth adjuster counterclockwise
ALIBRATE
YST
EM
A2
Rotate the depth adjuster
counterclockwise.
Front view of combinator
Depth adjuster