12
Glass (untreated)
5-15%
Plastics
10-15%
Wood
10-40%
Brick
10-40%
Concrete
40-80%
Metal
90-100%
5.Final Installation of Sensors
Integrated outdoor transmitter installation.
Professional Wireless Weather Station can be used in both the Northern and Southern Hemi-
spheres.
Prior to installation, you will need to calibrate the wind direction.
5.1. Northern Hemispheres (NOR).
The cardinal directions (N, S, E, W) molded on the body of the outdoor sensor are indicators
for the Northern Hemisphere only.
Step 1:
There is a “S” indicator on the wind vane that indicates South, as shown in Figure 13.
Align this “S” marker in the direction of South.
Step 2:
Console operation is set to Northern Hemispheres (
NOR
in the time area) in Location
division.
Note:
There are four alphabet letter of “N”,”E”,”S”and “W” around the wind direction,
representing for the direction of North, East, South and West. Wind direction sensor has to be
adjusted so that the directions on the sensor are matching with your real location. Permanent
wind direction error will be introduced when the wind direction sensor is not positioned cor-
rectly during installation.
Содержание RGT-SQ02
Страница 15: ...Figure 15 ...