BESANTEK
- - - - - -
TEST
Start/Stop
�
�
Provided, the TESTER is ON, when the
TEST Start/Stop is depressed, the selected
TEST will start (if stopped) or stop (if in
progress). The TEST Start/Stop also has the
EnerSave features. What that mean, is that
if you depress the TEST Start/Stop key for
more than 3 second, while starting the test,
then, the test will be carried up to a duration
of 1 minute (long Test). But, if you depress
the TEST Start/Stop Key for less than 3
second, or just depress it, than the instrument
will enter the EnerSave mode, and the test
duration is limited to about 10 seconds. In
both cases, the Test is stopped automatically
by the instrument, but the user can always
override the auto-stop, by depressing the
TEST Start/Stop key at any time, in any mode.
Range Indication by LED:
Test Current 1A
Resistance 0-2.000mn (2000uQ)
When this LED lights up, the instrument
will measure up to 1999uQ and will display
it as milli ohms. The resistance which can
be measured using this scale/range is from
o.ooom to 1.999mn.