Complies with ANSI/BHMA A156.10 and ANSI/BHMA A156.19 standard for Power

Assist and Low Energy Power Operated Doors.

UL325 & UL991 Listed

1009937-EI-1.0 – Issue 2013-02-10

ASSA ABLOY, the global leader in door opening solutions

Содержание SW200i

Страница 1: ...rvice Manual Original instructions Complies with ANSI BHMA A156 10 and ANSI BHMA A156 19 standard for Power Assist and Low Energy Power Operated Doors UL325 UL991 Listed 1009937 EI 1 0 Issue 2013 02 1...

Страница 2: ...Inc AB Copying scanning alterations or modifications are expressly forbidden without the prior written consent of the applicable company within ASSA ABLOY Entrance Systems US Inc AB Rights reserved f...

Страница 3: ...identification 20 8 Arm systems 23 9 Options 27 10 Pre installation 29 11 Mechanical Installation 50 12 Electrical connection 60 13 Start up 66 14 Changing group of parameters 70 15 Classification 71...

Страница 4: ...1 Revision Following pages have been revised Revision 1 0 Page This is the first version of the OHC Besam SW200i Installation and Service Manual 1009937 EI 1 0 Issue 2013 02 10 4 1 Revision...

Страница 5: ...ystems The door is designed to offer continuous use a high degree of safety and maximum lifetime For use see User manual 1007717 2 2 Safety precautions Do not climb on door parts Do not let children p...

Страница 6: ...necessary the user should consult the dealer or an experienced electronic technician for addi tional suggestions ASSA ABLOY Entrance Systems US Inc products are equipped with electronics and may also...

Страница 7: ...lication variable between 2 12 seconds Opening time 0 80 variable between 4 12 seconds Closing time 90 10 1 5 30 seconds HOLD open time 4 F to 113 F 20 C to 45 C Ambient temperature Max 95 Relative hu...

Страница 8: ...is fully open at back check it slows automatically to low speed The motor stops when the selected door opening angle has been reached The open position is held by the motor If the door is obstructed...

Страница 9: ...y The range of the POAS is depending on the spring pre tension 4 4 5 Push and go PAG DIP switch to select Push and Go ON or OFF Push and Go is available from any door position Push and Go is not activ...

Страница 10: ...ther a normally open contact with GND as reference or a normally closed contact with QTST as reference depending of group of parameters see page 66 4 5 2 Function of locks The lock output only works w...

Страница 11: ...rogram mode OFF or manually opened door Power Failure Mode or during KILL function 4 6 2 Presence detection swingpath door mounted Door mounted presence sensor swing side DMPS SS Whenasensorthatismoun...

Страница 12: ...tion Usedtoindicateanopenorclosedpositionofthedoor Theindicationpositionissetbyadjusting the inhibit blanking potentiometer Panic bar Parameter group 14 15 and 16 1009937 EI 1 0 Issue 2013 02 10 12 4...

Страница 13: ...grated and concealed in the header above the door The door can be opened in a direction opposite to normal in an emergency panic breakout Manual reset by pushing the door back into normal operation se...

Страница 14: ...ht hand Right hand Left hand 6 2 Door handing Door handing is determined by standing with your back to the hinges The side that the door nor mally opens right or left is the handing of the door The il...

Страница 15: ...rming Screw 1701704 4 Screw M6x20 93 09 723187 5 PEM Nut S 0420 2Z1 30 09 310 6 Screw CR FHMS 0 25 20x0 375x0 375 N 40 09 200 7 Transmission Unit 1007291 8 Clamp and Bolt Assembly 1009607 9 CU 200 Con...

Страница 16: ...1008593 2 End Plate OHC Bottom Load 1008612 3 M6x30 PFH Thread Forming Screw 1701704 4 Screw M6x20 93 09 723187 5 Screw 1 4 20x1 PFH TRS 52 09 004 6 Breakaway Device Assy 1008600 7 Connection Box Ass...

Страница 17: ...ighten mounting bracket hardware Controller Remove 4 M4 X 8 SHCS and 4 oval nuts out of bag and attach to controller orient oval nuts horizontally Oval nuts should be orientated per below for tighteni...

Страница 18: ...ication use M5 X 10 PHCS to mount junction box directly to top of header no mounting plate is required Panic Breakaway Device Required on all OHC inswing door packages Use hardware provided to mount p...

Страница 19: ...op Required on all OHC outswing door packages P N 1010090 Use hardware provided to mount door stop to header in order to stop doors at closed position 19 Issue 2013 02 10 1009937 EI 1 0 7 Part identif...

Страница 20: ...8 Arm systems 8 1 OHC Arm Kit Can be used on OHC Bottom Load and Readyfold door packages P N 1009345 8 2 Offset Pivot Arm Kit Pull Arm Kit P N 1007251 1009937 EI 1 0 Issue 2013 02 10 20 8 Arm systems...

Страница 21: ...8 3 Push Arm Kit P N 1007241 8 4 Pas Arm Kit P N 1007247 PAS Arm RH P N 1007476 PAS Arm LH 21 Issue 2013 02 10 1009937 EI 1 0 8 Arm systems...

Страница 22: ...ther Not jamming not rebated This door type has doors that always can move independently of each other and can be opened and closed synchronously Doubleegress Thisdoortypehasdoorsthatopensindifferentd...

Страница 23: ...02 102 P N 75 02 107 PRESS TO OPEN P N 75 02 108 P N 75 02 280 9 1 2 Remote transmitter push plates PUSH TO OPEN P N 75 02 273 PUSH TO OPEN P N 75 02 272 PUSH TO OPEN P N 75 02 269 PUSH TO OPEN P N 75...

Страница 24: ...nccable determineswhichoftheoperatorsistheMASTER and SLAVE MASTER SLAVE Red Black P N 331003583 9 3 Accessories Surface mounting box P N 655806 PS 4C P N 655845 3 position switch P N 75 15 310 Clear P...

Страница 25: ...o loose parts that might cause user to trip or fall Keep traffic path clear 6 Inspect door s overall condition The appropriate signage should be present Guide rails and finger guards should be in good...

Страница 26: ...Product label P N 1008999 1009937 EI 1 0 Issue 2013 02 10 26 9 Options...

Страница 27: ...r Unpack the operator and make sure that all parts are delivered in accordance with the packing note 10 3 Summary Installation Thisisonlyasummaryoftheinstallationprocess Seetherestofthismanualfordetai...

Страница 28: ...urisdiction Thinner wall profiles must be reinforced with rivnuts 10 5 Test Equipment Stopwatch Force gauge 50 lb 22 7 kg force range Multimeter 10 6 Tools required Set of box end wrenches Spirit Leve...

Страница 29: ...of Pivot Socket Y Pivot Height X Finish Floor Level FFL Header Length L a Measure the height of the door DH b Measure from the bottom of the door to the receiving surface of the pivot socket Y Subtra...

Страница 30: ...1009937 EI 1 0 Issue 2013 02 10 30 11 Mechanical Installation...

Страница 31: ...Lock screw 5 Door leaf 1 Threshold optional 6 Jamb wall 2 Header housing 3 Drive arm 4 31 Issue 2013 02 10 1009937 EI 1 0 11 Mechanical Installation...

Страница 32: ...ivot and the centerline of the drive shaft are aligned Alt 2 Tip Use plumb bob 11 1 4 Installation of Door Leaf for Side load and Bottom Load a Adjust the bottom pivot using instructions found in sect...

Страница 33: ...and shaft adapter All dimen sions given here correspond to an opening angle of 90 100 operator with push arm on a right handed door shown left handed door mirror image See page 47 for slide track mou...

Страница 34: ...the jamb header non pivot side preferable for the operator and arm system e Install the header using appropriate screws or if required Riv Nuts Be sure the header is level left to right as well as fro...

Страница 35: ...electrical connections see page 50 j Make all final adjustments sensors gaps etc to the door package in accordance to ANSI re quirements k Re Install cover 35 Issue 2013 02 10 1009937 EI 1 0 11 Mecha...

Страница 36: ...ll dimensions given here correspond to an opening angle of 90 100 The operator is shown with push arm on a left handed door right handed door mirror image Frame depth Standard Extension 3 3 4 95 mm 40...

Страница 37: ...10 lbf ft 14 Nm I I I I I I I I I I I I I I I I I I Align markings on drive arm and telescopic arm to achieve 40 degrees between the arms 37 Issue 2013 02 10 1009937 EI 1 0 11 Mechanical Installation...

Страница 38: ...11 3 3 Push Arm System Main arm 3 Telescopic part 4 Arm shoe 5 1009937 EI 1 0 Issue 2013 02 10 38 11 Mechanical Installation...

Страница 39: ...learance holes for 1 4 6 mm bolts and cable inlet to be drilled on site 1 Offset pivot or butt hinge 2 Pivot butt hinge centerline CL1 Drive shaft centerline CL2 39 Issue 2013 02 10 1009937 EI 1 0 11...

Страница 40: ...ual push Clearance holes for 1 4 6 mm bolts and cable inlet to be drilled on site 1 Offset pivot or butt hinge 2 Offset pivot butt hinge centerline CL1 Drive shaft centerline CL2 1009937 EI 1 0 Issue...

Страница 41: ...e reveal or distance from the wall line to the door leaf should be standard All dimensions given here cor respond to an opening angle of 90 100 operator with pull arm on a right handed door shown left...

Страница 42: ...re predrilled field installation requirements will dictate what type and size hardware to attach header to wall 1 Offset pivot or butt hinge 2 Adjust during installation 3 Slide Track 5 Drive shaft ce...

Страница 43: ...cable inlet are predrilled field installation requirements will dictate what type and size hardware to attach header to wall 1 Offset pivot or butt hinge 2 Adjust during installation 3 Slide Track 5...

Страница 44: ...al or distance from the wall line to the door leaf A should not exceed 4 1 4 108 mm All dimensions given here correspond to an opening angle of 90 100 operator with pull arm on a right handed door sho...

Страница 45: ...re predrilled field installation requirements will dictate what type and size hardware to attach header to wall 1 Offset pivot or butt hinge 2 Adjust during installation 3 Slide Track 5 Drive shaft ce...

Страница 46: ...cable inlet are predrilled field installation requirements will dictate what type and size hardware to attach header to wall 1 Offset pivot or butt hinge 2 Adjust during installation 3 Slide Track 5...

Страница 47: ...the door the guide shoe 1 will move a certain distance on the door Mark the end positions for this distance Note The end positions do not always occur when the door is fully closed and fully open d P...

Страница 48: ...11 3 6 Push Pull Arm System double egress 1009937 EI 1 0 Issue 2013 02 10 48 11 Mechanical Installation...

Страница 49: ...or butt hinge 2 Offset pivot butt hinge center line CL1 Adjust during installation 3 11 3 7 Fixing screw When the arm installation is ready the fixing screw must be tightened with 37 lbf ft 50 Nm C L...

Страница 50: ...d be stripped according to the instructions for the used wire connector Be aware local code shall be followed Connect the white neutral wire of the power installation cable with the AWG18 white neutra...

Страница 51: ...ther wires This wire will not be used d Connect the three green wires using a wire nut 4 e Connect the two white wires using another wire nut 5 f Adjust all wires neatly into box and reinstall the cov...

Страница 52: ...13 14 11 12 6 9 19 Cut the black wire 16 15 18 17 8 Electrician Notice Mains Power behind this cover Connect to White Neutral Black HOT Green GND Do not connect to RED Slave Master Mains power Cut th...

Страница 53: ...ction Mat safety Inner impulse controlled by Inner impulse 0 VDC Ground Overhead presence detection Overhead presence sensor incl 24 V LOUT and Safety Impulse Hold open time DIP switches shown in OFF...

Страница 54: ...al 2 9 16 5 1 8 65 130 mm Pulling PULL 1 0 1 0 PULL 3 3 4 95 mm Reveal 0 2 9 16 0 65 mm PULL 2 3 4 70 mm Reveal 0 2 9 16 0 65 mm Pulling PULL PAS 1 0 1 1 PULL 3 3 4 95 mm Reveal 2 9 16 5 1 8 65 130 mm...

Страница 55: ...on top of the control unit CU 200 separately or combined EXU SA EXU SI CU 200 5 mm nut driver Torx T10 Electrical power contact Tag strip long 2 pcs EXU short 1 pc EXU Note After changing replacing a...

Страница 56: ...kill reset jumper on Battery monitoring Lock release 2 Locked without power OFF with power ON Lock 12 V OFF 24 V ON DIP switches shown in OFF position Lock kick 1 0 VDC Ground 24 VDC Independentofswit...

Страница 57: ...KILL OUT Lock indication or Open closed door indication see above 24 V 1 A Sensor monitoring and reference for KILL NC Presence detection NC DMPS SS 1 Presence impulse NC DMPS NS 1 Ground Remove strap...

Страница 58: ...page 22 12 3 7 Settings for double doors Settings on the Function SLAVE MASTER Common X Program selection X Opening time X Closing time X Hold open time X Close Continue to open when the door is obstr...

Страница 59: ...er impulses can be connected to either MASTER or SLAVE CU or both The OPD OPS is to be connected to the MASTER CU except for Double egress where each OPD OPS must be connected to corresponding CU Door...

Страница 60: ...controlling the lock kick by turning the black plastic cam 2 when power is off This lock kick is optional and only used with fire doors to give a lock kick at power failure 2 1 13 1 Adjusting the door...

Страница 61: ...p block 1 Fine adjust if necessary with the screw on the stop arm 2 1 2 f When stop arm is on the bottom of the operator loosen the stop ring and the stop arm and let slide down Mount the stop arm on...

Страница 62: ...Note Impulses are not accepted if SPTE is more than 0 0 SPTE 1 3 2 Door stop arm 1 Stop block 2 Fine adjustment screw 3 1009937 EI 1 0 Issue 2013 02 10 62 13 Start up...

Страница 63: ...losed position 10 1 s 10 1 5 s Back check Latch check 13 2 1 Push the LEARN BUTTON LRN Remain clear of swing path of door as door may open and close rapidly The door has no safety during auto learn cy...

Страница 64: ...just the opening speed OPSP to comply with the applicable ANSI standard A156 10 or A156 19 Turning clockwise increases the speed see Table I on page 79 c Adjust the closing speed CLSP to comply with t...

Страница 65: ...MP DMPS NS NC PDET DMPS SS NC 24 VDC IMPULSE NO LOUT 1 2 3 4 5 PS 4C Kill switches With monitoring DMPS 24 VDC 0 VDC IMPULSE NO 0 VDC 24 VDC 0 VDC MONITORING 5 1 4 4 0 VDC COM 1 1 Timer Door mounted O...

Страница 66: ...to the parameter group number see table After a short pause the LED will repeat the group number and so on f Pushing the LEARN BUTTON once increases the parameter group number When the highest paramet...

Страница 67: ...On On LOCK RETRY In OFF EXIT and In OFF EXIT and In AUTO mode In AUTO mode In AUTO mode In AUTO mode In AUTO mode In AUTO mode In OFF EXIT and AUTO mode In AUTO mode In AUTO mode In AUTO mode In AUTO...

Страница 68: ...red back check g Remove the stop h The door reverts to closed position 14 2 Revert to default values for back and latch check a Disconnect the electrical power contact b Press the LEARN BUTTON and kee...

Страница 69: ...arm fixing screw d Moving the door towards open position reduces the tension or Moving the door towards closed position increases the tension e Tighten the drive arm f Turn the potentiometer SPTE to...

Страница 70: ...Push the button until you get the requested classification Disconnect the mains plug Next time you connect the mains the operator will use the new classification 15 4 Classification table 2 1 Classif...

Страница 71: ...The door does not close Remove objects in the detection zone Presence impulse is activated Remove object Something jammed beneath the door a Turn up the potentiometer SPTE until it is pos sible to loo...

Страница 72: ...ncoder cable Encoder error Four 0 3 s flashes pause etc Open and close the door manually and thereafter check the automatic function If the operator is still out of function replace the drive unit Che...

Страница 73: ...e to have a reliable and safe product Service and adjustments will ensure a safe and proper operation of an automatic door unit The table below shows the recommended interval in months when to replace...

Страница 74: ...ble egress doors or a pair of doors is installed in a hallway no guide rails are required if the distance between the wall and the door in the 90 degree open position does not exceed 10 in Exception 4...

Страница 75: ...shall be located between 6 and 28 in above the finish floor and not more than 8 in from the lead edge of the door panel in the full open position 8 2 2 2 2 When using a door mounted presence sensor th...

Страница 76: ...opped power operated swinging door from moving in the direction of closing shall not exceed a 30 lbf 133 N measured 1 in from the lock edge of the door at any point in the closing cycle 10 2 8 In the...

Страница 77: ...274 AUTOMATIC DOOR 11 2 2 An International DO NOT ENTER sign shall be visible from the side of doors that swings towards pedestrians attempting to travel in the wrong direction mounted on the door at...

Страница 78: ...ter and with black lettering on a yellow background ILL 02272 58 5 C L Apply to the approach side of the door AUTOMATIC DOOR 75 20 100 DO NOT ENTER AUTOMATIC DOOR AUTOMATIC DOOR CAUTION 75 20 102 AUTO...

Страница 79: ...ired to prevent a stopped door from opening or closing shall not exceed 15 lbf 67 N measured 1 in 25 mm from the latch edge of the door at any point during opening or closing The kinetic energy of a d...

Страница 80: ...m both sides of the door with the words AUTOMATIC CAUTION DOOR see illustration below The sign shall be a minimum of 6 inches 152 mm in diameter with black lettering on a yellow background Additional...

Страница 81: ......

Страница 82: ...A ABLOY Entrance Systems US Inc AB 1900 Airport Road Monroe NC 28110 US Tel 704 290 5520 Fax 704 290 5544 Tel 877 237 2687 service Tel 866 237 2687 sale www besam usa com marketing na besam assaabloy...