background image

 

 

- 2 - 

V. 2.0 

1. GENERAL RULES 

 
a)  This Manual gives instructions on the use and maintenance of the pump; 
b)  Any  person  using  the  pump  is  expected  to  be  conversant  with,  and  observe  the 

relevant legislative provisions currently in force in the country where the pump is to be 
used.  They are also required to follow the instructions set out in this Manual with care; 

c)  This Manual is based on, and complies with, technical knowledge applicable as at the 

date of sale of the product and shall not be considered inadequate for the sole reason 
that it has been up-dated on the basis of new knowledge/experience. 
IDROMECCANICA  BERTOLINI  has  the  right  to up-date  its  products  and their  related 
manuals without being thereby obliged to up-date previous products and manuals, save 
in cases deriving exclusively from safety considerations. 

d)  You  may  consult  our  "Technical  Assistance  Service"  in  relation  to  any  query  or  need 

arising  when  using  or  maintaining  the  product  and  to  obtain  assistance  in  choosing 
accessories to use with it. 

e)  No  part  of  this  Manual  may  be  reproduced  without  the  written  permission  of 

IDROMECCANICA BERTOLINI S.p.A 

 
Take care to observe the warnings carrying the following symbols: 

Safety  Rules  and  Measures  for  the  protection  of  the  user  or  others  against 

personal injury and/or for the protection of the pump against damage. 

 

Instructions for facilitating the effecting of the related Operation.  
Technical Information 

 

Warnings of an ecological nature. 

 
 
 

2. Product Description 

 
"IDB"
  Series  membrane-semi-hydraulic  piston  pumps  have  been  manufactured  with 
materials  that  make  them  particularly  adapted  for  the  application  of  disinfestations  and 
pesticide treatments and the spraying of flowers and vegetable crops. 
Together with their accessories, they are easy to fit to tractors, spraying and  weed-killing 
units and  to both thermal and electric motors. 
The  pumps  in  the  "IDB"  range  are  made  on  the  basis  of  modern  technology  but  without 
forgetting  the  lessons  of  the  past.    They  include  noble  materials  such  as  bronze  and 
stainless steel, combining flexibility of use with easy and practical maintenance. 

Содержание IDB 1100

Страница 1: ...for having chosen IDB Bertolini This use and maintenance Manual is made up of the following chapters 1 General Rules 2 Product Description 3 Technical Characteristics 4 Choice of type of pump and the...

Страница 2: ...and to obtain assistance in choosing accessories to use with it e No part of this Manual may be reproduced without the written permission of IDROMECCANICA BERTOLINI S p A Take care to observe the warn...

Страница 3: ...maximum 6 Factory number 7 Flow capacity at Maximum pressure in U S Gallons per Min 8 Maximum flow capacity 0 bars in U S Gallons per Min 3 1 Identification of Components When in doubt it will be of a...

Страница 4: ...4 V 2 0 IDB 1100 IDB 1100S IDB 1250 Three membranes IDB 1400 IDB 1600 IDB 1800 IDB 2000 Five membranes 9 IDB1100s IDB 1400 1600 1800 2000 if present 9 IDB1100 1250 IDB 1400 1600 1800 2000 if present...

Страница 5: ...products currently on sale in the market in the concentrations advised by the manufacturers Cf table at page 23 The technical data relating to the pumps performance characteristics no revs l flow capa...

Страница 6: ...ich are completely water tight It is strongly advised that mechanically pre fastened high pressure hoses should be fitted on the delivery side in order to ensure maximum safety while the plant is func...

Страница 7: ...delivery side hoses connected to the use function machinery An opening of the connection with the using apparatus can cause significant damage to persons animals or property in the vicinity Check the...

Страница 8: ...accumulator on the pump if fitted or on the delivery side pressure side is automatically pre loaded at a pressure of 6 8 bars usable for the pump s maximum working pressure For any different working p...

Страница 9: ...r 3 metres should be avoided using hoses of appropriate length and section without sharp bends It is advisable that they should also be pre filled that is already full of water In such circumstances i...

Страница 10: ...ix an anti freeze of a type used with cars with the cleaning water This will protect the pump even in relation to any liquid residues left inside it The pump and system components hoses clamps connect...

Страница 11: ...ump Collect residues and dispose of them regularly No residue must be introduced into the drainage system or soil The replacement of materials such as membranes oil suction and delivery side valves an...

Страница 12: ...17 spanner to unscrew the membrane locking screw Remove the locking screw the clearance disk and the membrane Wash the interior according to the state of deterioration with diesel c When removing the...

Страница 13: ...ld be made after 500 hours of use following the steps set out below a Remove the filling and discharge plugs b Leave the oil to drain out rotating the pump shaft manually c It is advisable to clean th...

Страница 14: ...condition O Check accumulator pressure O Check of plant hoses and connections O Check and clean filters O Check pump fitting O Check membrane and possible replacement S Change oil S 500 hours Check su...

Страница 15: ...aft protection WARNING Information relating to personal safety READ THIS WITH CARE The choice of the motor cardan shaft protective safety cones on Bertolini pumps is dependant on two fundamental facto...

Страница 16: ...ue the shorter version is preferable in that this facilitates the fitting of the cardan shaft QUOTA A B Protrusion of shaft protection safety cones MM PUMPS IN FRONT DELIVERY SIDE BEHIND SUCTION SIDE...

Страница 17: ...motor x K N B for any special installation or use refer to Bertolini s Technical Assistance Service to avoid annoying difficulties WARNING All electrical connections must be carried out by specialise...

Страница 18: ...ntact of the liquid with the internal parts of the pump when this is not required leads to a accelerated deterioration of the pump Do not operate at a maximum speed greater than that indicated on the...

Страница 19: ...e guarantee is only valid where it has been possible for the defect to be verified by our Customer Assistance Service and where not deriving from improper use or failure to maintain the pump Those par...

Страница 20: ...blocked Make the pump turn with delivery open to evacuate air Clean or replace the valves The water pumped out is irregular the pressure gauge oscillates The air chamber is under inflated Inflate the...

Страница 21: ...to the discharge position by pass WARNING IT IS ESSENTIAL TO COMPLY WITH THIS RULE OTHERWISE THE GUARANTEE ON THE PUMP IS INVALIDATED b Turn the regulator knob anti clockwise to reduce the pressure to...

Страница 22: ...nsidered as providing a general guide and not an absolute guarantee The information is not based on room temperature or performance but only on resistance to the chemical agents At the time of printin...

Страница 23: ...etic Acid 20 D C Acetic Acid 80 D C Acetic Acid C C Acetic Anhydride D A Acetone D D Acetylene2 A A Acryionitrile C D Alcohols Amyl A A Benzyl A D Butyl A A Diacelone2 D D Ethyl A A Hezyl A A Isobutyl...

Страница 24: ...anufacturer Company Address Town Send within 15 days Only at that point will the guarantee be operative Law 675 96 protection of persons and other parties with respect to the processing of personal da...

Отзывы: