![Berthoud RAPTOR 2540 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/berthoud/raptor-2540/raptor-2540_manual_2739292007.webp)
7
82.490 - Raptor
RAPTOR
2540
RAPTOR
3240
RAPTOR
4240
RAPTOR
5240
S
Series
O
Option
Not available
PUMP
OMEGA dual turbine centrifugal pump for PTO regulation
(dual control: interior and exterior)
Flow rate: 550 litres/minute at 3 bar
Max. pressure: 8 bar
TANKS
Main tank
2500 l
3200 l
4200 l
5200 l
Rinsing tank
260 l
440 l
450 l
450 l
Handwash tank
S
S
S
S
FILLING AND FILTRATION
Filling by manhole or external suction
S
S
S
S
Incorporation hopper (25 litres) and cans rinsing with hydraulic
lifting
S
S
S
S
Filling filter filtration (sieve, 8/10 mesh)
S
S
S
S
Delivery filter filtration (1/4 turn filter, 4/10 mesh)
S
S
S
S
Delivery filter double filtration (booms from 36 m)
S
S
C-TRONIC
REGULATION (see manual No. 82.510)
Electronic regulation using the BUS CAN technology.
The
C-TRONIC
box can control all the functions of the
sprayer.
-PILOT
multifunction wireless joystick (boom and spraying
control)
S
S
S
S
IMPLEMENTATION
BERLOGIC
with
DUALMATIC
: manually-controlled valve
blocks
S
S
S
S
DUALELEC IV
: motorised valve blocks (see manual No. 82.487)
O
O
O
O
DUALELEC V
: motorised valve blocks (see manual No. 82.487)
O
O
O
O
Electric mixing disconnect control
O
O
O
O
Electric mixing disconnect control and
NIVOMATIC
gauge with
filling automatic stop
O
O
O
O
External washing with automatic hose reel
O
O
O
O
GAUGES
NIVELEC
gauge (see manual No. 82.494)
S
S
S
S
NIVOMATIC
gauge with buzzer (see manual No. 82.494)
O
O
O
O
NIVOMATIC
gauge with buzzer and filling automatic stop (see
manual No. 82.494)
O
O
O
O
BOOMS
AXIALE II boom (see manual No. 82.486)
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
DDL II boom (see manual No. 82.488)
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
24 - 28 - 30
32/33 m
AXIALE boom (see manual No. 82.515)
36/38 m
36/38 m
EKTAR B2 boom (see manual No. 82.513)
36/38
40/42 m
36/38
40/42 m
EKTAR B3 boom (see manual No. 82.514)
36/38 m
36/38 m
Resetting the slope correction (AXIALE II / DDL II)
O
O
O
O
Resetting the variable geometry (AXIALE II / DDL II)
O
O
O
O
Содержание RAPTOR 2540
Страница 2: ...2 82 490 Raptor...
Страница 27: ...27 82 490 Raptor 1 2 3 6 5 2 6 5 7 R B E 1 4 3...
Страница 34: ...34 82 490 Raptor...
Страница 35: ...35 82 490 Raptor 6 OTHER SPRAYER FUNCTIONS...
Страница 39: ...39 82 490 Raptor 17 18 4 4 1 2 3 20 7 8 21 9 6 5 19...
Страница 46: ...46 82 490 Raptor...
Страница 47: ...47 82 490 Raptor 8 SPRAYING CIRCUITS...
Страница 49: ...49 82 490 Raptor 35 19 75 9 35 35 75 35 35 35 3 5 35 35 35 40 19 1 4 6 7 8 5 2 17 9 15 16 12 13 10 14 11 9 3...
Страница 51: ...51 82 490 Raptor 35 19 75 9 35 35 75 35 35 35 3 5 35 35 35 40 19 1 4 6 7 8 5 2 17 9 15 16 12 13 10 14 11 3...
Страница 53: ...53 82 490 Raptor...