![Berthoud HERMES 1000 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/berthoud/hermes-1000/hermes-1000_manual_2739289020.webp)
20
82.526 - HERMES
5.7 PERIODIC MAINTENANCE TABLE
Inspection points
Every
treatment
Monthly
After winter
storage
Before winter
storage
Rinse the tank
X
X
Rinse the spraying circuit
X
X
X
Clean the suction filter
X
X
Clean the delivery filter
X
X
Clean the nozzles
X
Check the road signals
X
Apply moisture repellent product to electrical connectors
X
X
X
Clean and grease transmissions (universal joint)
X
(or max. 50h)
X
X
Condition of cables
X
X
Condition of safety devices
X
X
Alignment of nozzle carriers and nozzles
X
X
Alignment of the boom arms
X
X
Grease friction parts
X
X
Grease mechanical joints
X
Oil level in pump
X
Clean the drip preventer
X
Clean the outside
X
Check the flow through nozzles
X
Check the drip preventer
X
Drain the pump
X
Check the pressure in the nitrogen lifting bulb (depending
on boom)
X
5.8 WINTER STORAGE OF THE SPRAYER
• The sprayer must be clean before winter storage.
• Rinse the entire circuit thoroughly (with the cleaning
product) ( 4.5, page 17).
• Drain the tank.
• Rinse with clean water.
• Completely drain the fluid circuit, making sure that
the pump is not operated for too long without water
(2 minutes maximum).
• Protect from frost by adding the necessary quantity
of anti-freeze to provide the level of protection
required.
• When adding anti-freeze, take into consideration
the residual volume in the circuit pipework.
• Run the pump at idling speed.
• Operate all valves in all positions, so as to protect
the pump valves, regulator, filters and pipes.
• Open the sprayer to let anti-freeze into the boom.
When the anti-freeze reaches the nozzles, stop
spraying and disengage the power take-off.
• Check the level of protection using an anti-freeze
tester, by taking a sample and adjusting the
dosage, if necessary.
• Grease or oil metal parts and moving parts where
rust can occur.
• Remove oxidation from contacts on electrical
connectors (BERTHOUD reference 765.065,
aerosol KF F2).
• Clean
the
outside
of
the
equipment
( 5.4, page 19), re-paint any bare mechanical
parts (BERTHOUD reference 769.077 for the
blue paint aerosol or 778.890 for the green paint
aerosol).
• Store the equipment out of the sun and sheltered
from bad weather on flat, firm ground.
Содержание HERMES 1000
Страница 22: ...22 82 526 HERMES 7 SPRAYING CIRCUIT...
Страница 25: ...82 526 HERMES 25...