6
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adapting to different types of gas
APPLIANCE CATEGORY: II2H3+
Burner
Type of Gas
Pressure
Nozzle
Nominal Charge
Reduced Charge
Diameter
diameter
by-pass
1/100mm
mbar
1/100mm
g/h
l/h
Kw
kcal/h
kw
kcal/h
Town
G110 8
192 - 397
1,75
1505 0,44 378
31
reg
Semi-
Natural
G20 20
101 - 167
1,75
1505 0,44 378
31
reg
Rapid
Butane G30
28
66
127
-
1,75
1505
0,44
378
31
Propane
G31 37
66 125 - 1,75
1505 0,44 378
31
Town
G110 8
280 - 681 3 2580 0,75 645
42
reg
Natural
G20 20
129 - 286 3 2580 0,75 645
42
reg
Rapid
Butane G30
28
87
218
-
3
2580
0,75
645
42
Propane
G31 37
87 214 - 3 2580 0,75 645
42
Town
G110
8
130 - 181
0,8 688 0,30 258
27
reg
Dual Natural
G20
20
70
-
76 0,8 688
0,30
258
27
reg
burner
Butane G30
28
46
211
-
0,8
688
0,30
258
27
inner Propane
G31
37
46 207 -
0,8 688
0,30
258
27
Town
G110
8 2x300 - 885
4,4
3784 1,8 1548 65
reg
Dual Natural
G20
20
2x110 - 419 4,4 3784
1,8
1548
65
reg
burner
Butane G30
28
2x69
298
-
4,1
3526
1,8
1548
65
outer Propane
G31
37
2x69 293 -
4,1 3526
1,8
1548
65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Descriptions
DESCRIPTIVE CAPTION FOR HOB (fig.11)
1. Dual burner
2 Griddle
3. Rapid burner
4. Medium burner
5. Dual out burner control knob
6. Dual in burner control knob
7. Rear element griddle control knob
8. Front element griddle control knob
9. Rapid burner control knob
10. Medium burner control knob
Содержание PM3630GX
Страница 19: ...19 Fig 1 Fig 2 Fig 3 Fig 3A Fig 3B ...
Страница 20: ...20 Fig 4 Fig 5A Fig 5B Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 ...
Страница 21: ...21 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 ...
Страница 22: ...22 Fig 19 ...