12
GAS
CONNECTION
All
gas
connections
must
comply
with
national
and
local
codes.
The
gas
supply
line
(service)
must
be
the
same
size
or
greater
than
the
inlet
line
of
the
appliance.
This
range
uses
a
1/2"
NPT
inlet
(see
drawing
below
for
details
of
gas
connection).
On
all
pipe
joints
use
appropriate
sealant
resistant
to
gas.
This
range
can
be
used
with
Natural
or
LP/Propane
gas.
The
range
is
shipped
from
the
factory
for
use
with
natural
gas.
For
LP/propane
household
installation,
the
appliance
must
be
converted
by
the
dealer,
by
a
factory
‐
trained
professional
or
by
a
qualified
licensed
plumber
or
gas
service
company.
Gas
conversion
is
important
for
safe
and
effective
use
of
the
appliance.
It
is
the
responsibility
of
the
dealer
and
the
owner
of
the
range
to
perform
the
appropriate
gas
conversion
following
the
directions
of
the
manufacturer.
THE
GAS
CONVERSION
PROCEDURE
IS
DESCRIBED
IN
THIS
MANUAL
AND
IN
THE
PACKAGE
CONTAINING
THE
CONVERSION
NOZZLES
SHIPPED
WITH
EVERY
RANGE.
Please
provide
the
service
person
with
this
manual
before
work
is
started
on
the
range.
WARNING!
DO
NOT
USE
AN
OPEN
FLAME
WHEN
CHECKING
FOR
LEAKS!
Leak
testing
of
the
appliance
shall
be
conducted
according
to
the
manufacturer's
instructions.
Before
placing
the
oven
into
operation,
always
check
for
leaks
with
soapy
water
solution
or
other
acceptable
method.
Check
for
gas
leakage
with
soapy
water
solution
or
other
acceptable
methods
in
all
gas
connections
installed
between
inlet
gas
pipe
of
the
appliance,
gas
regulator,
till
to
the
manual
shut
‐
off
valve.
MANUAL
SHUT
‐
OFF
VALVE
THIS
VALVE
IS
NOT
SHIPPED
WITH
THE
APPLIANC
AND
MUST
BE
SUPPLIED
BY
THE
INSTALLER.
The
manual
shut
‐
off
valve
must
be
installed
in
the
gas
service
line
between
the
gas
hook
‐
up
on
the
wall
and
the
appliance
inlet,
in
a
position
where
it
can
be
reached
quickly
in
the
event
of
an
emergency.
In
Massachusetts:
A
'T'
handle
type
manual
gas
valve
must
be
installed
in
the
gas
supply
line
to
this
appliance.
FLEXIBLE
CONNECTIONS
In
case
of
installation
with
flexible
couplings
and/or
quick
‐
disconnect
fittings,
the
installer
must
use
a
heavy
‐
duty,
AGA
design
‐
certified
commercial
flexible
connector
of
at
least
1/2"
(1.3
cm)
ID
NPT
(with
suitable
strain
reliefs)
in
compliance
with
ANSI
Z21.41
and
Z21.69
standards.
In
Massachusetts:
The
unit
must
be
installed
with
a
36"
(3
‐
foot)
long
flexible
gas
connector.
In
Canada:
use
CAN
1
‐
6.10
‐
88
metal
connectors
for
gas
appliances
and
CAN
1
‐
6.9
M79
quick
disconnect
device
for
use
with
gas
fuel.
PRESSURE
TEST
‐
POINT
STOPPER
VALVE
To
avoid
gas
leaks,
the
pressure
test
‐
point
stopper
valve
and
gasket
supplied
with
the
range
must
be
installed
on
the
gas
fitting
at
the
back
of
the
range
according
to
the
diagram
below.