Electrical Data
Rated isolation voltage
U
i
250 V
Conventional thermal current
I
the
10 A at 30°C / 3,5 A at 70°C
Rated supply voltage
U
e
230V AC
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein-ag.de
Template: 0850174292 Orig. 2
Utilization category
AC-15, 230 V AC/3 A
Direct opening action
acc. IEC/EN 60947-5-1, annex K
Short circuit protection
melting fuse 4A gL/gG
Protection class
II, protective insulation
Mechanical Data
(The data refer to a SHS3 with fixed switching point)
Switch PBT
Hinge
G-X5CrNi19-10
Ambient temperature
-25°C to +70°C (connecting cable permanently mounted)
Contact function
Slow make and break contacts
2 N.C., 1 N.O.
Mechanical life
10
6
operations
Switching frequency
Max. 300 operations/h
Mounting
4 x M6 screws DIN EN ISO 7984
On flat and stiff ground
Wiring
Fixed connecting cable 6 x 0,75 mm² x 5 m
Bending radius = 60 mm min.
Weight
≈
0,65 kg
Mounting position
Any
Protection class
IP 67 acc. IEC/EN 60529
Switching angle
+/- 3° from fixation point for the N.C. contacts
and 9° for the N.O. contact
Forced disconnect angle
6°+2° from fixation point in both directions
(for 0°-3° only in Plus-direction,
for 267°-270° only in Minus-direction)
Forced disconnect torque
1,5 Nm
Mechanical load
F
R1
= max. 1200 N
( for direction of loaded forces see the illustration below )
F
R2
= max. 500 N
F
A
= max. 1200 N
The SHS3 features a swivel range of 0°-270°.
Within this range the switching point is free selectable.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EU-Conformity
F
A
F
R1
90°
F
R2
180°
270°
0°
BG,
C
CSA
US
(in preparation)
Approvals