4
WC-SUPPORT FRAME G3005A
TECHNICAL DRAWING
To place the expansion anchors, drill holes in the wall and floor.
Water connection with lateral arrangement
The cistern is connected to the water supply
via the angle valve.
Thread of the angle valve: G ½“
Mounting wall
Support Frame
529 mm
500 mm
460 mm
375 mm
230 mm
180 mm
H1
H2
790 mm
768 mm
165 ~ 200 mm
Ø
110 mm
Top edge
Finished floor
0 ~ 120 mm
400
+20
-10
The dimensions of H1 and H2 are variable and depend on the WC.
Theoretical dimension of
the wall brackets for the
outer mounting variant.
(529 / 423) mm
Theoretical dimension of
the wall brackets for the
inner mounting variant.
375 mm
A
B
a
(
a
) Dimension according to the actual orientation of the flush pipe.
Note: The above holes are theoretical dimensions for frame mounting.
Please refer to the actual position of your frame.
768 mm
A
ø
10x75 mm
A
A
The wall brackets A can be
mounted inside or outside.
The drilling distance is different.
Top edge
Finished floor
Drill holes
Ø
10x75 mm
►Insert expansion anchors ►Fasten the brackets
B
B
ø
10x75 mm