Installation
Electrical data of the unit
Unit with 1,0 – 1,5 kW nominal power
HOT-STAR single phase (Voltage 25% / -10%)
El. Connection
Colour
Frequency
Fuse
Phase
Brown, black or 1
50 Hz / 60 Hz
-
N
Blue or 2
PE
Green/yellow
Functional conditions
o
max. tolerance of the mains voltage/nominal voltage
+5%/-10%
o
Frequency
50 / 60 Hz
o
Protection class
IP 41
Installation environment
-
max. environmental temperature
storage
>-20°C to +70°C
in function
>+5°C to +35°C
-
max. relative humidity
storage
> 10% to 90%
in function
> 30% to 90%
Installation conditions
The unit must be positioned/built-in on a straight and even surface, in a horizontal
position. The work top or positioning surface must allow a load of ≥ 100 kg of weight.
Please make sure the unit can be disconnected form mains easily at all times.
Installation regulations
Please carefully follow and respect these regulations:
-
Check the voltage on the installation spot and make sure it suits the voltage indicated
on the technical data plate.
-
The electrical installation must meet the local building regulations. The national
regulations of the electrical supplier must be followed and respected.
-
The unit comes with a power cable with plug that must be connected to the socket.
-
If residual current circuit breakers are used, they must be designed for a residual circuit
current of at least 30mA.
-
The unit must not be placed on or near a hot surface.
-
The operational personnel must ensure that all installation, maintenance and inspection
are made by trained and authorised personnel.
-
The unit is equipped with a power cable and plug that meets local regulations.
Make sure the socket is equipped with a protective conductor!
The electrical connection of the unit must follow and respect the
national regulations of the country of installation!
Attention
Wrong voltage could
damage the unit!
Attention
The electrical connections must be made by
trained and authorized personnel.