148
Touch Screen
Mobile Panel User's Manual V 1.5
4. Touch Screen
4.1 3M Touch
This touch screen is used in 8.4" Mobile Panel designs.
Property
Enable switch
Manufacturer
Type
idec
HE5B-M2
Environmental Temperature
Operation
Storage
Transport
-25 °C to +60° C
-40 °C to +80 °C
-40 °C to +80 °C
Humidity
Operation
45% to 85% (non-condensing)
Altitude
Max. 2000 meters
Operating Voltage AC/DC
Max. 125 V
Operating Current
AC
DC
Max. 0.5 A at 125 V resistive load
Max. 0.3 A inductive load
Max. 1 A at 30 V resistive load
Max. 0.7 A inductive load
Minimum Operating Requirements
3 V AC/DC, 5 mA
Insulation Resistance
100 MOhm
Vibration
Operation
5 to 55 Hz, 0.5 mm amplitude
Shock
Operation
Max. 100 m/s²
Impact Resistance
At least 250 N
Lifespan
Mechanical
Electrical
Position
1)
0 -> 1 -> 0: At least 1 million operations
Position
0 -> 1 -> 2 -> 0: At least 100000 operations
1) For switch positions, see table 23 "Switch positions for the enable switch" on page 61.
Standards
IP65 protection according to IEC60529
IEC60947-5-1
EN60947-5-1
JIS C8201-5-1
UL508
CSA C22.2 No. 14
ISO12100/EN292
IEC60204-1/EN60204-1
ISO11161/prEN11161
ISO10218/EN775
ANSI/RIA R15.06, B11.19
Table 76: Technical data for enable switch
Содержание 4MP181.0843-03
Страница 2: ...2 Mobile Panel User s Manual V 1 5...
Страница 4: ...4 Mobile Panel User s Manual V 1 5...
Страница 6: ...6 Mobile Panel User s Manual V 1 5...
Страница 128: ...128 Accessories Compact Flash cards 5CFCRD xxxx 02 Mobile Panel User s Manual V 1 5 Figure 57 SanDisk White Paper page 3...
Страница 130: ...130 Accessories Compact Flash cards 5CFCRD xxxx 02 Mobile Panel User s Manual V 1 5 Figure 59 SanDisk White Paper page 5...
Страница 134: ...134 Accessories USB Memory Stick Mobile Panel User s Manual V 1 5...
Страница 144: ...144 Maintenance Servicing Changing the Battery Mobile Panel User s Manual V 1 5...
Страница 160: ...Model Number Index 160 Mobile Panel User s Manual V 1 5...