3. Motor switch /operating mode
Switch position 0
Motor off
Switch position I
Manual operation (ON/OFF) for wet/dry vacuuming operation
Switch position II
Automatic operation for pond and cleaning
a) After switching on, the motor will suck for 30 seconds.
b) Motor stops after approximately 30 seconds to drain.
c) Auto Start after 30 seconds.
d) Repetition (a) and (b) to OFF (0)
4. Pond Cleaning
Please proceed as follows when using the device for pond cleaning:
Position the device at a safety clearance of 2 metres away from the waters edge.
Screw the discharge hose (3) securely onto the water discharge hole on the base of the collection
tank (8). Attach the dirt collecting bag (4) to the end of the discharge hose and place in such a way
that the water can easily flow down a drain or to a suitable location in the garden, as silt is generally
accepted as being an excellent general fertilizer. Coarse dirt will be collected in the dirt collection
bag (4). Depending on the degree of dirt, the dirt collecting bag (4) should be emptied at regular
intervals whilst cleaning the pond, and emptied and cleaned at the end of each use.
Open the two locking clips (6) on the side of the collection tank (8) and remove the motor head (1). Fit
the filter sponge (13) over the motor head (1). Tighten the cord around the motor head. Place the
motor head back onto the collection tank, ensuring the locking clips are relocated back into the
corresponding indents on the collection tank, with the electrical cable positioned on the opposite side
to the suction hose plug-in connector hole (7).
Push the plug-in connector on the suction hose (9) into the connection hole (7) on the top of the
collection tank and lock the connection by a half turn to the right.
Connect the required number of suction tube extensions (10) to the suction hose (9) and attach the
transparent suction nozzle (12) to the end of the suction tube extensions (10).
Once the above has been completed, plug the device into the RCD. Place the lance into the part of
the pond to be cleaned. To start the motor, push the switch (2) to position 11 AUTOMATIC.
After a working interval of approximately 30 seconds, the motor switches off for approximately 30
seconds
in order for the water to drain out of the collection tank (8). During this time, you can
reposition your lance in a different part of the pond which requires cleaning.
The device will operate on this cycle until switched to the OFF position (0). Always remove the plug
from the RCD when the device is not in use.
Dirt and water should be thoroughly removed from the inside of the collection tank (8) at the end of
each use.