31
Connection
Connection of RolloTec
®
insert with IR remote control extension.
Important: As long as an UP command is applied to extension input ‘2’ the louver
cannot be actuated manually or automatically on the unit itself.
Connection of RolloTec
®
insert with ‘central control’.
Example A for 2 louver motors:
Insert
with RolloTec
®
timer. Inserts
and
with RolloTec
®
radio control pushbutton
or RolloTec
®
pushbutton.
The automatic and manual control of both motors is effected ‘centrally’ through insert
by an RolloTec
®
timer. The switching commands are evaluated for both motors in the
same way. Common moving up or down of the motors connected is facilitated (e. g. a
central UP command in the mornings and a central DOWN command in the evenings
for all Venetian blind motors connected).
Motors M1 (insert
) and M2 (insert
) can, in addition, be manually operated by a
RolloTec
®
radio control pushbutton or a RolloTec
®
pushbutton.
As shown in the wiring diagram, further inserts can be added. Observe the
connected loads of the automatic cut-outs.
Important: As long as an UP command is applied to extension input ‘2’ the louver
cannot be actuated manually or automatically on the unit itself.
30
Connection
4. Connection
Recommendation: To interconnect two inserts use 5x1.5 mm² wiring (1, 2, L, N, PE)
between the inserts.
Connection of RolloTec
®
insert.
Connection of RolloTec
®
insert with mechanical extension (mechanically
locking louver push-button).
When louver push-buttons are used, the RolloTec
®
insert will not go to self-holding
(continuous running). The louver will have to be moved into the desired position by
actuating the push-button manually.
If this is not desired use mechanically locking louver switches.
Important: As long as an UP command is applied to extension input ‘2’ the louver
cannot be actuated manually or automatically on the unit itself.