5.2 Commissioning
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Testing the detection area
picture 8: Adjusters on the rear
The insert is installed correctly. Mains voltage not yet switched on.
o
Make the test settings (picture 8). Run-on time adjuster: 10 s; Brightness adjuster on
3
icon; Adjuster
Sens.
to max.
o
Attach the motion detector cover and frame to the concealed insert.
o
Switch on mains voltage
The motion detector carries out a self test for approx. 90 seconds.
o
Leave the detection area and observe the switching behaviour.
If the motion detector switches on, then sources of interference must be hidden (see
Limiting the detection area) or the sensitivity reduced.
o
Measure the detection area.
If the detection area is too large, limit the detection area (see Limiting the detection area).
If the detection area is too small, expand the detection area using an extension.
o
Make the operating settings for the run-on time, sensitivity and brightness threshold.
Setting the brightness threshold
The brightness threshold is infinitely adjustable in a range from approx. 0 to 150 lux and day
operation
3
. In so doing, the
3
symbol stands for brightness-independent switching and the
2
symbol for switching in case of darkness.
o
Remove the motion detector cover from the concealed insert.
o
Turn the adjuster (6) to the required position (picture 8).
i
Should the motion detector no longer react to detected movements in Night mode,
2
setting, turn the adjuster back somewhat towards
3
.
o
Attach the motion detector cover and frame to the concealed insert.
Seite 8/10
22.07.2010
82540231
97-82640-201
BLC
BLC motion detector comfort 1.1 m