picture 4 

The operating mode switch can be locked in the 

AUTO

 position using a locking screw (8) on the 

back of the top. 

For this, screw in the supplied screw from the rear side of the cover into the intended 
opening (8). 
The position of the operating mode switch can no longer be changed. 

Changing the brightness threshold with the Teach function 

The Teach function can be used to save the current ambient brightness as a brightness 
threshold. The value set on the Brightness setter (6) is then no longer evaluated. Additional 
saving operations overwrite the previous value.  

A power failure of more than 2 seconds or removing the cover from the insert causes the 
loss of the saved brightness threshold. The brightness threshold set on the adjuster (6) is 
reactivated. 

If a brightness value of more than 150 lux is saved as the brightness threshold, then the 
motion detector is in Day mode and switches irrespectively of the brightness. 

picture 5: Activating the Teach function 

Activating the Teach function: completely cover the motion detector three times within 
9 seconds(picture 5). 

Seite 5/10 

22.07.2010 

82540231 
97-82640-201 

BLC 
BLC motion detector comfort 1.1 m 

Содержание BLC 1784 Series

Страница 1: ...ime take into account all circuit breakers that supply dangerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage The load is not ele...

Страница 2: ...2 wire or installation button With the dimmer insert it is possible to change the brightness using a 2 wire extension insert Switch on brightness can be saved with the dimmer insert With the dimmer in...

Страница 3: ...n on time i If the run on time setting dial 5 is set to M Short time operation then the light is switched on for approx 0 5 seconds even if the button is pressed for longer Switch light on with minimu...

Страница 4: ...ith Continuous off switch on via the extension is not possible Setting the Continuous on operating mode o Switch the operating mode switch to the I position The lighting remains permanently switched o...

Страница 5: ...6 is then no longer evaluated Additional saving operations overwrite the previous value i A power failure of more than 2 seconds or removing the cover from the insert causes the loss of the saved brig...

Страница 6: ...s 5 1 Fitting and electrical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the correspondin...

Страница 7: ...pand the detection area connect a 3 wire extension insert with motion detector cover see instructions for 3 wire extension insert The motion detector of the main unit also evaluated recorded motions o...

Страница 8: ...g the detection area or the sensitivity reduced o Measure the detection area If the detection area is too large limit the detection area see Limiting the detection area If the detection area is too sm...

Страница 9: ...is used then dimming will take place after the run on time has elapsed and the lighting will switch off after approx 30 seconds If during dimming movement is detected then the motion detector switche...

Страница 10: ...the detection area Cause Interference sources in the detection area e g heating ventilation cooling light bulbs Reduce the detection area with a cover panel or reduce the sensitivity with the Sens adj...

Отзывы: