1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 
The load is not electrically isolated from the mains even when the device is switched off. 

Do not press on the sensor window. Device can be damaged. 

The device is not suitable for use as a burglar alarm or other alarm. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

picture 1 

Seite 1/10 

BLC motion detector comfort 1.1 m 

82540231 
97-82640-201 

22.07.2010 

BLC 

Содержание BLC 1784 Series

Страница 1: ...ime take into account all circuit breakers that supply dangerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage The load is not ele...

Страница 2: ...2 wire or installation button With the dimmer insert it is possible to change the brightness using a 2 wire extension insert Switch on brightness can be saved with the dimmer insert With the dimmer in...

Страница 3: ...n on time i If the run on time setting dial 5 is set to M Short time operation then the light is switched on for approx 0 5 seconds even if the button is pressed for longer Switch light on with minimu...

Страница 4: ...ith Continuous off switch on via the extension is not possible Setting the Continuous on operating mode o Switch the operating mode switch to the I position The lighting remains permanently switched o...

Страница 5: ...6 is then no longer evaluated Additional saving operations overwrite the previous value i A power failure of more than 2 seconds or removing the cover from the insert causes the loss of the saved brig...

Страница 6: ...s 5 1 Fitting and electrical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the correspondin...

Страница 7: ...pand the detection area connect a 3 wire extension insert with motion detector cover see instructions for 3 wire extension insert The motion detector of the main unit also evaluated recorded motions o...

Страница 8: ...g the detection area or the sensitivity reduced o Measure the detection area If the detection area is too large limit the detection area see Limiting the detection area If the detection area is too sm...

Страница 9: ...is used then dimming will take place after the run on time has elapsed and the lighting will switch off after approx 30 seconds If during dimming movement is detected then the motion detector switche...

Страница 10: ...the detection area Cause Interference sources in the detection area e g heating ventilation cooling light bulbs Reduce the detection area with a cover panel or reduce the sensitivity with the Sens adj...