Blind insert comfort

6.  Appendix
6.1  Technical data

Rated voltage  

AC 230 V, + 10 % /- 15 %

Mains frequency 

50/60 Hz

MCB 

max. 10 A

Switching current 

5 A (R/L)

Change-over time to the opposite running direction 

0.6 sec.

Standby power consumption 

< 0.1 W

Relative humidity 

0 ... 65 % (no condensation)

Operating temperature 

-5°C … +45°C

Storage/transport temperature 

-20°C … +60°C

Extension unit cable length 

max. 50 m

Load cable length 

max. 100 m

Number of extension units 

unlimited

Connecting terminal 

1 x 4 mm² or 2 x 2.5 mm²

Mounting orientation 

connecting terminals downwards

Housing installation depth 

22 mm 

Claw guide installation depth 

32 mm

6.2  Accessories

Push-button for blinds 

order no. 8524 11 xx

Blind time switch 

order no. 8574 11 xx

Radio push-button for shutters quicklink 

order no. 8524 51 xx

Radio shutter timer quicklink 

order no. 8574 51 xx 

6.3  Warranty

We reserve the right to make technical and formal changes to the product in the interest of 

technical progress. 
Our products are under guarantee within the scope of the statutory provisions. 
If you have a warranty claim, please contact the point of sale or ship the device postage free 

with a description of the fault to the appropriate regional representative. 

Содержание 8522 11 0 Series

Страница 1: ... electric shock Do not operate device without application module If several drives should be connected in parallel to one output it is mandatory to observe the manufacturer s data use a cut off relay where required Motors could be destroyed Use blind drives with mechanical or electrical final position switches only Check final position switches for correct adjustment Observe motor manufacturer s d...

Страница 2: ...buttons for blinds blind inserts key push buttons for blinds Only suitable for use in indoor areas with no drip and no spray water Installation into wall box according to DIN 49073 Operate with suitable application module see Chapter 6 2 Accessories Product characteristics 2 mechanically and electrically mutually locked relay contacts 4 Operation These instructions describe the installation of the...

Страница 3: ...protection Circuit shutter insert according to circuiting diagram Figure 2 Mount shutter insert in wall box recommended deep box The connecting terminals must be at the bottom Attach frame and application module see instructions for application module Control by sensors Sensors such as wind precipitation sensors are used e g to protect awnings from damage If a threshold is exceeded on the sensors ...

Страница 4: ...ension unit Individual control with push button for blind extension unit according to circuiting diagram 503520 Individual control with key push button for shutter extension unit Circuit individual control with key push button for shutter extension unit according to circui ting diagram ...

Страница 5: ...rt Master and group control Circuit master and group control according to circuiting diagram Master control under application of various RCCBs Circuit master control under application of various RCCBs according to circuiting diagram ...

Страница 6: ...m Mounting orientation connecting terminals downwards Housing installation depth 22 mm Claw guide installation depth 32 mm 6 2 Accessories Push button for blinds order no 8524 11 xx Blind time switch order no 8574 11 xx Radio push button for shutters quicklink order no 8524 51 xx Radio shutter timer quicklink order no 8574 51 xx 6 3 Warranty We reserve the right to make technical and formal change...

Отзывы: