Electrical

6

Connection diagram for dual voltage, single-phase
motors. Your dual-voltage motor’s terminal board (under
the motor end cover) will match one of the diagrams
below. Follow that diagram if necessary to convert motor
to 115 Volt power. 
Connect power supply wires to L1 and L2. For 3-phase
motors, or if motor does not match these pictures, follow
the connection diagram on the motor nameplate.

MOTOR SWITCH SETTINGS

Dual-voltage motors (motors that can operate at either
115 or 230 volts), are set at the factory to 230 volts. Do
not change motor voltage setting if line voltage is 230
volts, or if you have a single voltage motor. 

NOTE:

Never wire a 115 volt motor to a 230 volt line.

REMOVE MOTOR END COVER

If you have a dual-voltage motor, and will connect it to
115 volts, follow the procedure below.

You will need to remove the motor end cover to change
the voltage setting. 
Your motor terminal board (located under the motor end
cover) should look like one of those below. 

PLUG TYPE VOLTAGE SELECTOR  

To change to 115 volts:
1. Make sure power is off.
2. Pull the plug straight up.
3. Move and attach the plug at the 115 volt position.

The plug will now cover 2 metal tabs. The arrow on
the plug will point to 115V.

4. Attach the power lead wires to the power lead termi-

nals. Make sure the wires are secure.

5. Attach the ground wire to the green ground screw
6. Reinstall the Motor end cover
Go to Wiring Connections below.

DIAL TYPE VOLTAGE SELECTOR  

To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in the

dial window.

3. Attach the power lead wires to the power lead termi-

nals. Make sure the wires are secure.

4. Attach the ground wire to the green ground screw
5. Reinstall the Motor end cover
Go to Wiring Connections below.

Hazardous voltage. Can shock, burn, or

cause death. Disconnect power to motor before work-
ing on pump or motor. Ground motor before connect-
ing to power supply.

WIRING CONNECTIONS

Ground motor before connecting to electrical

power supply. Failure to ground motor can cause

severe or fatal electrical shock hazard.

Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn

OFF power to motor before working on electrical

connections.

Supply voltage must be within ±10% of nameplate

voltage. Incorrect voltage can cause fire or damage

motor and voids warranty. If in doubt consult a licensed
electrician.

Use wire size specified in Wiring Chart, Page 7. If

possible, connect pump to a separate branch circuit

with no other appliances on it.

Wire motor according to diagram on motor name-

plate. If nameplate diagram differs from diagrams

above, follow nameplate diagram.

For All 3-phase Motors:

Follow the wiring diagram on

the motor junction box or on the motor nameplate. For
575 volt installations, consult a licensed electrician.

Figure 6: Removing Motor End Cover

Figure 7: Voltage set to 230 volts, Plug Type 

Motor  
End Cover

 End Cover Screws

V

oltage Change 

Pl

u

g

Gro

u

nd 

Scre

w

Po

w

er Lead

Terminals

Figure 8: Voltage set to 230 volts, Dial Type 

Voltage  
Change Dial

Ground 
Screw

Power Lead
Terminals

Содержание 10LTHH

Страница 1: ...AL Self Priming Centrifugal Pump 2007 BE536 Rev 5 2 07 LTHH Series Installation Operation Parts For further operating installation or maintenance assistance Call 1 262 728 9181 293 Wright Street Delav...

Страница 2: ...pressure hazard and possible injury do not use in a pressure tank domestic water system Do not use as a booster pump pressurized suction may cause pump body to explode Do not allow pump or piping syst...

Страница 3: ...leg ambient compen sated extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and Berkeley s WICOR s only duty is to repair or replace defective...

Страница 4: ...Add sections of pipe as needed using Teflon tape on male threads Be sure that all suction pipe is leakproof or pump will lose prime and fail to pump Install foot valve 10 to 20 feet below the lowest l...

Страница 5: ...NSTALLATION NOTICE Use only Teflon tape or Teflon based joint compounds for making all threaded connections to the pump itself Do not use pipe joint com pounds on plastic pumps they can react with the...

Страница 6: ...ECTOR To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Attach the power lead wires to the power lead termi nals Make sure the wire...

Страница 7: ...d ly which could cause injury or property damage Disconnect power before servicing motor 9 If this procedure or the wiring diagrams are confusing consult a licensed electrician PRIMING THE PUMP NOTICE...

Страница 8: ...all pressure in system and refill pump and piping with cold water Pump and piping need not be disconnected to repair or replace motor or seal see Figure 13 If motor is replaced replace the shaft seal...

Страница 9: ...ber Cup on ceramic seat with liquid soap Be sparing 3 Put clean cardboard washer on seal face With thumb pressure press ceramic seal half firmly and squarely into seal cavity See Figure 18 Polished fa...

Страница 10: ...diffuser on seal plate with two screws 13 Follow instructions under Pump Reassembly PUMP REASSEMBLY 1 Clean gasket surfaces on pump body and seal plate install new gasket 2 Slide motor seal plate ass...

Страница 11: ...all connections on suction line 3 Leaking foot valve 3 Replace foot valve Pump has lost prime through In installation already in use 1 Air leaks 1 Check all connections on suction line and shaft seal...

Страница 12: ...14SS C30 47SS C30 14SS C30 14SS 7 Diffuser 1 C101 276P C101 276P C101 182 C101 182 7A Screw 10 24 x1 Lg Hex Head 2 U30 696SS U30 696SS 7A Machine screw 8 32x7 8 Lg 2 U30 53SS U30 53SS 8 Diffuser Ring...

Страница 13: ...a amor age automatique 2007 BE536 R v 2 5 07 S ries LTHH Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 262 728 91...

Страница 14: ...eau domestique Ne pas utiliser cette pompe en tant que pompe de surpression le corps de la pompe risque d ex ploser si l aspiration est mise sous pression Ne pas laisser geler la pompe ni aucun autre...

Страница 15: ...tre les surcharges thermiques d clenchement extra rapide trois pieds et temp rature ambiante compens e de la dimension recommand e ne sont pas utilis s notre garantie sera annul e Le seul recours de l...

Страница 16: ...aspiration puis les abaisser dans le puits Ajouter d autres longueurs de tuyaux selon le besoin en enveloppant tous les filets m les de ruban t flon S assurer que tous les tuyaux d aspiration sont ta...

Страница 17: ...s pression ni l utiliser en tant que pompe de surpression INSTALLATION DE LA POMPE NOTA Pour le branchement de tous les raccords filet s sur la pompe n utiliser que du ruban t flon ou de la p te d tan...

Страница 18: ...teur gauche jusqu ce que 115 apparaisse dans la fen tre du cadran 3 Brancher les fils d alimentation sur les bornes S assurer que les fils sont bien retenus en place 4 Brancher le fil de mise la terre...

Страница 19: ...sse de fonctionner le protecteur contre les surcharges thermiques risque de red marrer inopin ment ce qui risque de causer des blessures ou des dommages mat riels Toujours couper le courant avant d in...

Страница 20: ...la pression du syst me puis refaire le plein de la pompe et des tuyaux avec de l eau froide Pour r parer le moteur ou le remplacer ainsi que les joints la pompe et les tuyaux doivent tre d branch s F...

Страница 21: ...quide 3 Mettre la rondelle en carton propre sur la surface d tanch it Avec la pression des pouces pousser fermement la moiti du joint en c ramique d querre dans la cavit du joint du dissipateur voir l...

Страница 22: ...tructions figurant sous Remontage de la pompe REMONTAGE DE LA POMPE 1 Nettoyer les surfaces d appui du joint sur le corps de la pompe et la plaque d tanch it poser un joint neuf 2 Glisser l ensemble m...

Страница 23: ...le cas d une installation d j en service 1 cause de prises d air 1 V rifier tous les raccords du tuyau d aspiration et le joint de l arbre 2 parce que le niveau d eau est plus 2 Abaisser le tuyau d a...

Страница 24: ...C101 182 C101 182 7A Vis de 10 24 po x 1 po de long 2 U30 696SS U30 696SS 7A Vis m taux de 8 32 x 7 8 po de long 2 U30 53SS U30 53SS 8 Bague du diffuseur 1 C21 10 C21 10 C21 2 C21 2 9 Corps de la pom...

Отзывы: