ELECTRICAL OPERATION
COMPONENT FUNCTION
Keypad Assembly . . . .
Controls electrical power to knife motor on all models and auto motor on automatic
models.
Thermal Switch . . . . . . .
Shuts down slicer if knife motor overheats.
Carriage Sensor
(X13AE, X13A) . . . . . . . .
Detects when carriage is in home position and detects when auto mode has been
engaged.
Slide Bar Switch . . . . . .
Detects when product table is installed/ removed.
Control Board . . . . . . . .
Controls operation of all electrical components.
Circuit Board . . . . . . . . .
Provides circuit protection for power supply.
Automatic Motor
(X13A, X13AE) . . . . . . . .
Drives automatic slicing mechanism.
Timer Assembly
optional) . . . . . . . . . . . . . .
Provides auto shutoff feature if no slicing for 15 seconds.
ERROR CODE TEST
1.
Error codes are designated by the number of times the red pilot light on the keypad flashes. To reset, push
the STOP button.
No. of
Flashes
Problem
Probable Cause
1
High temperature detected on control board. Replace control board.
2
Over current detected in control board.
DC motor shorted or control board malfunction: Replace
both control board and DC motor.
3
Knife motor over temperature.
Check for malfunctioning knife motor.
4
Auto motor internal hall effect malfunction.
Replace DC motor.
5
Auto motor internal hall effect transition
malfunction.
Replace DC motor.
6
Encoder input not active.
Replace DC motor.
7
Unable to find home.
Malfunctioning carriage switch, or malfunctioning plate flex
cable, or no magnet in base.
8
Carriage moving too fast or slow.
Check J9 cable, or check flex cable, or clean round rail.
9
Clutch disengaged while running.
Re-engage auto or adjust eccentric pin.
10
Slide bar guide switch not engaged.
Check or adjust slide bar guide switch.
WIRING DIAGRAMS WITH
SEQUENCE OF OPERATIONS
X13 & X13E Sequence of Operation
X13 SLICER - ELECTRICAL OPERATION
F25332 Rev. A (0718)
Page 32 of 36