CIRCUIT BREAKER TEST
Certain procedures in this section require
electrical test or measurements while power is
applied to the machine. Exercise extreme caution
at all times. If test points are not easily accessible,
disconnect power and follow lockout / tagout
procedures, attach test equipment and reapply
power to the test.
1.
Place slicer on its side, so it is resting on motor
housing.
2.
Remove screws to access control board.
Fig. 84
3.
Plug slicer in.
4.
Verify 120VAC between J1-1(power cord
neutral) and circuit breaker voltage in, circuit
breaker voltage out.
5.
If voltage is not present at circuit breaker voltage
in, replace the power cord.
6.
If voltage is present at circuit breaker in but not
out, replace circuit breaker.