15
Ensure that the hose is not subjected to twisting
which will affect the gas fl ow when using your gas grill. Also the hose must not
have undue tension and must not touch any part of the gas grill which may be hot.
Please choose for a
fl
exible hose whose heatproof is higher than 80° C
Best change every 2 years the
fl
exible hose or when the national conditions require it.
8. Connecting the Gas Cylinder
LP (Liquid Propane) Gas Supply Connection
1. Always place the propane cylinder on the tank brackets located on the right side of the cart.
2. Always confi rm that all burner control knobs are in the OFF position before activating the gas
supply.
3. Before connection, be sure that there is no debris caught in the head of the gas cylinder, head of
the regulator valve, or in the head of the burner and burner parts.
4. Always connect the gas supply regulators as follows: lnsert the nipple of the valve coupling into the
tank valve and tighten the connection collar by turning it clockwise with one hand while holding the
regulator with the other hand. (See diagram to right)
5. Disconnect the propane cylinder from the regulator valve when the grill is not in use.
6. Do not obstruct the fl ow of combustion air and ventilation air to the grill.
7. Keep ventilation openings of the cylinder enclosure free and clear from debris.
8. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on cylinder valve
outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
▲
DANGER
To prevent
fi
re or explosion hazard when testing for a leak:
1. Always perform the “leak test” before lighting the grill and each time the cylinder is connected for use.
2. Do not smoke or allow other sources of ignition in the area while conducting a leak test.
3. Conduct the leak test outdoors in a well-ventilated area.
4. Do not use matches, lighters or a fl ame to check for leaks.
5. Do not use grill until all leaks have been stopped, if you are unable to stop a leak, disconnect the propane supply, call for
gas appliance service or your local propane gas supplier.
▲
WARNING:
Always test gas line for leaks at connector with soap water fi nishing all connections.
Checking for Leaks
1. Make 6-9 cl (2-3 oz.) of leak solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the “OFF” position.
3. Spray some solution on the tank valve up to the regulator connection.
(See diagram to right).
4. lnspect the solution at the connections for bubbles. lf no bubbles appear,
the connection is secure.
5. lf bubbles appear, you have a leak. Go to step 6.
6. Disconnect the regulator from the tank and reconnect.
7. Retest wlth solution.
8. lf you continue to see bubbles, replace the cylinder.
!
!
Содержание 1032A-KC5B
Страница 3: ...3 2 Exploded View 40 ...