background image

Mic-Fi User’s Manual  

page 6 

4.2

 

 Wi-Fi Security Setup 

To change the Wi-Fi access password:  

1.

 

Open an internet browser, input 

http://10.10.1.1

 

and click “enter”. A pop-up window will require 

you to enter a username and password, please 

enter: 

admin

  and 

admin

, and then this window 

should appear: 

 

2.

 

Click          in the window to pop-up the screen:  

 

 

 

3.

 

Click “Network Security Settings” to pop-up the 

screen on the right. 

4.

 

Enter your desired Network Name (SSID) and 

password in “WPA-PSK Key” and “Re-Enter”, and 

click “Next”. The setting is done, now you can re-

connect the new SSID  Wi-Fi  by entering the new 

password. 

 

5.

 

The App on iPad/iPhone 

5.1

 

Installation on iPhone / iPad 

 

Search “Mic-Fi” in App Store to download and install it. 

Click the  

 icon to display video.

 

Warm-up Tips: If the live video is black or slow, please restart the App again. 

 

Capture photo or record video (The pixel resolution has to be set at 640x480 

when recording video). 

 

 

 

 

 

Navigation icon  -  moving a dot left/up/down/right for calibration or 

measurement operation. 

 

 

Photos folder or videos folder. 

 

Calibration and measurement. 

 

Switch between photo taking and video recording. 

 

 

    

Resolution Setting. (When changing the resolution, please  wait until the 

illumination LED is off and lights up again – it takes about 5 seconds). 

 

Содержание 8003-STD

Страница 1: ...Wi Fi DIGITAL MICROSCOPE USER S MANUAL DIGITAL Wi Fi MICROSCOPE N 8003 STD Bergeon SA T l 41 32 933 60 00 www bergeon ch 2400 Le Locle Suisse Fax 41 32 933 60 01 info bergeon ch USER MANUAL...

Страница 2: ...on Windows 12 7 3 Calibration on Windows Systems 13 7 4 Measurement on Windows Systems 14 8 Wi Fi microscope on Mac Computer 15 8 1 Installation on Mac Computer 15 8 2 Images on MAC 16 8 3 Calibratio...

Страница 3: ...product from electrostatic damage Do not attempt to disassembly any part of this product Do not attempt to service this product yourself Opening the covers may expose you to dangerous voltage points o...

Страница 4: ...d to PC or AC adaptor via MiniUSB cable Led Press for 2 seconds to switch from white led to UV led only for UVW model press and to increase or decrease the intensity of light Photo Press to capture th...

Страница 5: ...d please wait for about 5 seconds to open the application to see your images If there is no video display please close and restart the app again The Wi Fi indicator LED flashes and video stream signal...

Страница 6: ...can re connect the new SSID Wi Fi by entering the new password 5 The App on iPad iPhone 5 1 Installation on iPhone iPad Search Mic Fi in App Store to download and install it Click the icon to display...

Страница 7: ...the live video to show the following screen 1 Click to select a point and refine the selection by clicking the arrows 2 select in the same way a second point at a known distance in this way a line of...

Страница 8: ...lease don t adjust again the Focus Magnification wheel If the new photo object is not in focus please only adjust the distance between the microscope and the object until the photo is clear The measur...

Страница 9: ...the new photo object is not in focus please only adjust the distance between the microscope and the object until the photo is clear The measurement data can be saved inside the taken photo 6 3 Measure...

Страница 10: ...icture Take Stop Video Take time lapsed pictures Email the selected photos Save the selected photo or video file Or 7 1 1 File Menu Select a photo or video and click File on the menu bar Open Open the...

Страница 11: ...l the illumination LED is off and lights up again before clicking OK it takes about 5seconds Setting Change language The language selection allows you to select the interface language 7 1 3 Capture Me...

Страница 12: ...inary Segmentation Monochrome display Red Monochrome display Green Monochrome display Blue Calibration on Video To obtain the accurate measurement data for each magnification please calibrate before a...

Страница 13: ...hand scale box of the screen 5 In the live video window click on the calibration button then click and drag to 2mm length a small window pop up 6 Enter the actual length the example is 2mm and click O...

Страница 14: ...tart the next section double click to finish the polygon measurement Radius of Circle Measurement Allows you to measure the circumference area and radius of a circle Simply click and extend out to the...

Страница 15: ...0 8 or later version the system will pop up the message as below window You need to set your computer as below Click Apple icon to pop up the window on the right click System Preference to show the fo...

Страница 16: ...the software icon after completing installation Click Preview and then the main screen will display video it waits about 5 seconds to display the live video if the video is blank or slow please click...

Страница 17: ...ult magnification is 60x 4 Clicking the icon a warning message pop up and a blank box will appear in the right upper of the main window 5 Please click OK and enter the actual length 1mm as the example...

Страница 18: ...the desired radius Measurement Diameter Circle Allows you to measure the circumference area and radius of a circle Simply click and extend out to the desired diameter Measurement Three Points Circle...

Страница 19: ...ements Windows XP SP2 or later Available USB 2 0 or later port 10 2 Running USB Microscope Note Before start USB Microscope program please make sure USB digital microscope has been connected to PC via...

Страница 20: ...our files into the desired folder and file format Save all Save all your files in the photo or video folder into the desired folder Delete delete the selected image or video You will be prompted to co...

Страница 21: ...w area click Crosshair Scale Line Circle Grid on the drop down menu as below Snapshot Enable and Snapshot Disable the default is enable snapshot Suggestion If you need more performance of the video pr...

Страница 22: ...er second The number range is 1 30 2 Timer Limit it is the time of video recording to avoid video file size exceed to the space of disk The number range is 1 99999 3 Compress click it and you can sele...

Страница 23: ...n measurement feature allows measurement of a polygon Simply click and drag to form the desired length and click again to start the next section double click to finish the polygon measurement Radius o...

Страница 24: ...een found while opening the program the message please connect USB Digital Microscope will be shown If images from the microscope camera are not being transmitted and your display is still showing the...

Страница 25: ...stamp with jpg file The format of the time stamp filename is YYYYMMDDhhmmss jpg YYYY is the year MM is month DD is date hh is hour mm is minutes and ss is second The captured image will be inserted in...

Страница 26: ...ow If you select the left of the line and drag the mouse you can move the line Select the right of the line and drag the mouse you can increase or decrease the length of the line Angle Clicking the ic...

Страница 27: ...con the rectangle will display in the video preview window Selecting left region region 1 of the rectangle and dragging the mouse you can move the rectangle Selecting right region region 2 of the rect...

Страница 28: ...d extend out to the desired radius Measurement Diameter Circle The diameter of a circle measurement allows you to measure the circumference area and radius of a circle Simply click and extend out to t...

Страница 29: ...ame Rate 10fps 30fps Li ion Battery Continuous Working Time Appx 2 Hours Full Charging Time Appx 2 Hours Power Source DC5 0V 1A Camera Spec Camera Sensor CMOS 1 4 Optical features o Exposure Auto o Ga...

Страница 30: ...r changing the resolution a When changing the resolution please wait until the illumination LED is off and lights up again before clicking OK it takes about 5 seconds Please restart the app 6 Why does...

Страница 31: ...rchase The warranty is null and void if the damage is resulting from carelessness or misuse No compensation will be given by distributors if the product is returned during the warranty period In addit...

Отзывы: