1  SAFETY INFORMATION AND PRECAUTIONS

This manual and the operation manu-

al associated with it form integral parts 

of the product. Make sure that they are 

always kept with the boiler even if it is 

transferred to another owner or user, or 

re-installed elsewhere. If you damage or 

lose this manual, order a replacement 

immediately from your local Technical 

Assistance Service.

The boiler must only be installed and ser-

viced by qualified personnel, in conform-

ity to applicable legislation and applica-

ble technical standards.

The boiler must only be used for the pur-

pose for which it is designed. The man-

ufacturer declines all responsibility, con-

tractual or other, for damage to property 

or injury to persons or animals caused by 

improper installation, adjustment, mainte-

nance or use.

As soon as you open the packaging, 

check immediately that the contents are 

all present and undamaged. Contact the 

reseller from whom you purchased the 

product if you notice any problems.

The safety valve must be connected to a 

suitable collection and drain system. The 

manufacturer declines all responsibility 

for damage caused by the operation of 

an improperly connected safety valve.

The following instructions must be passed 

on to the user on installation of the boiler:

  - if water leaks from the boiler, turn off the 

water supply and contact the manufactur-

er’s Technical Assistance Service imme-

diately. 

  - periodically check that operating pres-

sure in the water circuit is over 1 bar. If 

necessary, contact the manufacturer’s 

Technical Assistance Service to arrange 

servicing by professionally qualified per-

sonnel. 

  - if the boiler is not going to be used 

for an extended period of time, contact 

the manufacturer’s Technical Assistance 

Service to have at least the following 

operations performed:

   •

 switch the boiler OFF at the control 

panel and at the mains power switch

   •

 close the boiler’s fuel cock, central heat-

ing circuit shut-off cock and domestic hot 

water circuit shut-off cock

   •

 empty the central heating circuit and 

domestic hot water circuit if there is any 

risk of freezing

  - the boiler must be serviced at least 

once a year. Servicing must be arranged 

in advance with the manufacturer’s 

Technical Assistance Service

Observe the following precautions to ensure 

safe operation of the boiler:

Do not allow children or uninformed per-

sons to operate the boiler

Do not operate any electrical devic-

es or equipment, including switches or 

domestic appliances, etc., if you can 

smell fuel or fumes. In the event of a 

gas leak, thoroughly ventilate the room 

by opening wide all doors and windows, 

close the gas shut-off valve and call 

the manufacturer’s Technical Assistance 

Service immediately to arrange urgent 

assistance by professionally qualified 

personnel

Do not touch the boiler while barefoot or 

wet

Never clean the boiler without first dis-

connecting it from the mains electrici-

ty supply by turning the mains power 

switch and the control panel switch OFF

Do not tamper with or adjust the boiler’s 

safety or control devices without prior 

authorisation and instructions from the 

manufacturer

Do not pull, disconnect, or twist the 

electrical cables coming from the boiler 

even if it is disconnected from the mains 

electricity supply.

Do not obstruct or restrict vents in 

the room where the boiler is installed. 

Adequate ventilation is essential for cor-

rect combustion.

Do not store containers of flammable 

substances in the room where the boiler 

is installed.

Do not dispose of packaging material 

into the environment, or leave it within the 

reach of children, since it can become a 

potential hazard. Dispose of packaging 

material in compliance with applicable 

legislation.

Содержание NOVELLA 55-64-71 RAP

Страница 1: ...Installation Manual NOVELLA 55 64 71 RAP Boilers Cast Iron Base EN Installation Manual...

Страница 2: ...2 The following symbols are used in this manual b CAUTION Indicates actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do...

Страница 3: ...diagram 12 3 INSTALLATION 13 3 1 Installation standards 13 3 2 Place of installation 13 3 3 Installation in existing system 13 3 4 Water connections 14 3 5 Electrical connections 14 3 6 Gas connectio...

Страница 4: ...ve at least the following operations performed switch the boiler OFF at the control panel and at the mains power switch close the boiler s fuel cock central heat ing circuit shut off cock and domestic...

Страница 5: ...ards and are enclosed in a functional control panel integrated in the body of the appliance NOVELLA boilers use total shut down logic and do not waste energy because they only start up when heat is a...

Страница 6: ...thermostat 5 Water circuit drain cock 6 Thermocouple 7 Burner 8 Gas supply solenoid valve 9 Name plate Key 10 Main switch 11 Central heating temperature control 12 Central heating temperature gauge 1...

Страница 7: ...ifications Temperature 15 C Pressure 1013 mbar Description 55 64 71 Rated heat input in central heating mode kW 61 0 70 5 79 0 kcal h 52460 60630 67940 Rated heat output in central heating mode kW 55...

Страница 8: ...installation and servicing may be ren dered difficult Fig 2 4 2 6 Material supplied The boiler is delivered in a wooden cage Proceed as follows to remove this remove the staples fixing the wooden cag...

Страница 9: ...6 unscrew the nut D from the top rear tie rod fig 2 7 fit the second lifting plate E over the end of the tie rod F Make sure that the sec ond lifting plate is diagonally opposite that fitted previousl...

Страница 10: ...8 Overall dimensions and water fittings Fig 2 9 2 9 Water circuit Key A Water circuit drain cock B CH circuit temperature control sensor C Safety thermostat sensor D CH circuit temperature gauge senso...

Страница 11: ...p of the right size bear in mind the boiler s water side pressure drop as shown in the following graph Fig 2 11 bOn initial start up and at least every year check that all the pumps in the system rota...

Страница 12: ...or automatic manual FU Fuse LV LED indicator mains power LR LED indicator flue gas temperature alarm TR Central heating temperature control TS Safety thermostat manual reset TF Flue gas thermostat man...

Страница 13: ...gas supplied The type of gas is specified on the packaging label and on the boiler s own name plate Make sure that the flue is able to withstand the temperature of the flue gases and that it has been...

Страница 14: ...5 Electrical connections Use a multi pole disconnector with a contact gap of at least 3 mm to connect the appliance to the mains electricity supply The appliance functions on an alternating current s...

Страница 15: ...necessary connection to the ter minal strip A Connect up the optional room thermostat and or timer as shown in the electrical wir ing diagrams in this manual Connect up the electrical power supply fig...

Страница 16: ...es are thor oughly clean Fit a suitably sized filter in the gas supply pipe if the gas supply contains any solid particles bThe gas supply line must be suitable for the flow rate demanded by the burne...

Страница 17: ...res condensate and mechanical stress bNOVELLA boilers are equipped with a flue gas thermostat located inside the hood This thermostat shuts down the boiler immediately in the event of flue gas blowbac...

Страница 18: ...he circuit until the pressure gauge reads out a value of 1 5 bar cold Close the water circuit shut off cocks fig 3 10 3 9 Emptying the water circuit Turn the electricity supply off by switching the bo...

Страница 19: ...l connections to the mains supply and to the system s control and safety devices have been made correctly check that the flue is properly constructed 4 2 Ignition Once you have completed all the prepa...

Страница 20: ...alve a number if times until the pilot burner lights fig 4 10 Hold down the ignition knob on the gas valve for about another 20 seconds after the pilot burner lights then release it Turn the ignition...

Страница 21: ...shown by the gas plate and have been calibrated in the factory using the values listed in the table tolerance 5 If the boiler needs new settings after repairs have been made the gas valve changed or...

Страница 22: ...disabled To do so proceed as follows Unscrew the screw D Screw the pressure regulator screw E all the way in Replace the plug D with the blind plug pro vided in the kit Unscrew the pressure measuremen...

Страница 23: ...ty the central heating system if there is any risk of freezing Contact your local Technical Assistance Centre if you encounter any problems in completing the above procedure IMPORTANT Also perform the...

Страница 24: ...ormally consists of the following operations remove encrustations from the burner remove encrustations from the heat exchangers check and clean the flue pipes check the efficiency of the external casi...

Страница 25: ...25 7 OPTIONAL ACCESSORIES Wall mounted weekly timer thermostat fig 7 1 RO120 storage cylinder fig 7 2 Back draught shutter 180 cod 480213 200 cod 480214 Fig 7 1 Fig 7 2 Fig 7 3...

Страница 26: ...26...

Страница 27: ......

Страница 28: ...proving its products and therefore reserves the right to modify the characteristics and specifications of the appliance described in this manual at any time and without prior notice The contents of th...

Отзывы: