Gas pressure
G20
G31
Nominal gas pressure
mbar
20
37
Hydraulic connections
HC input - output
Ø
3/4”
DHW input-output
Ø
1/2”
Gas input
Ø
3/4”
Boiler dimensions
Height
mm
780
Height with hydraulic cover connection
mm
845
Width
mm
400
Depth at shell
mm
358
Boiler weight
kg
39
Heating capacity
G20
G31
Heating air flow
Nm
3
/h
24,298
24,819
Heating gases flow
Nm
3
/h
26,304
26,370
Max - min. heating mass flue gas flow rate
gr/s
9,086-1,272
9,297-1,859
Domestic hot water capacity
G20
G31
Domestic hot water air flow
Nm
3
/h
34,017
34,746
Domestic hot water gas flow
Nm
3
/h
36,825
36,918
Max - min DHW mass flue gas flow rate
gr/s
12,720-1,272
13,016-1,859
Fan performance
0.85 m concentric pipes residual discharge head
Pa
50
0.5 m separated pipes residual discharge head
Pa
70
Residual discharge head of boiler without pipes
Pa
80
Concentric flue gas outlet pipes
Diameter
mm
60-100
Maximum length
m
7.8
Losses for a 45°/90° bend
m
1.3/1.6
Hole in wall (diameter)
mm
105
Concentric flue gas outlet pipes
Diameter
mm
80-125
Maximum length
m
20
Losses for a 45°/90° bend
m
1/1.5
Hole in wall (diameter)
mm
130
Twin flue gas outlet pipes
Diameter
mm
80
Maximum length
m
50+50
Losses for a 45°/90° bend
m
1/1.5
B23P-B53P Installation
Diameter
mm
80
Maximum discharge length
m
80
Collective smoke pipes under pressure (only with specific accessory)
Maximum allowed pressure in smoke pipe in the event of installation with collective smoke pipe
Pa
50
50
NOx class
5
Emission values at maximum and minimum gas flow rate (***)
G20
G31
Maximum
CO s.a. lower than
ppm
150
190
CO
2
%
9,0
10,0
NOx s.a. lower than
ppm
30
30
Temperature of the flue gases
°C
67
67
Minimum
CO s.a. lower than
ppm
10
20
CO
2
%
9,0
10,0
NOx s.a. lower than
ppm
25
35
Temperature of the flue gases
°C
57
55
(***) Check performed with concentric pipe Ø 60-100, length 0.85 m - water temperature 80-60°C.
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation lan-
guage.