ENGLISH
21
Multigas table
DESCRIPTION
Methane gas
(G20)
Propane
(G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
70,69
Net Calorific Value
MJ/m
3
S
MJ/KgS
34,02
-
88
46,34
Supply nominal pressure
mbar
mm W.C.
20
203,9
37
377,3
Supply minimum pressure
(25 C.S.I. - 30 C.S.I. - 12 R.S.I. - 25 R.S.I.)
mbar
mm W.C.
8
81,6
-
Supply minimum pressure
(38 C.S.I. - 15 R.S.I. - 35 R.S.I.)
mbar
mm W.C.
10
102,0
-
Mynute Green 25 C.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
n° - mm - mm
1 - 63 - 130
1 - 63 - 130
Diaphragm: number of holes - diameter of holes
n° - mm
1 - 6,7
1 - 4,7
Heating maximum gas capacity
Sm
3
/h
2,64
kg/h
1,94
DHW maximum gas capacity
Sm
3
/h
2,64
kg/h
1,94
Heating minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
DHW minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
Numbers of fan revolutions at slow start
rpm/min
3.400
3.400
Maximum number of fan revolutions (CH)
rpm/min
5.600
5.600
Maximum number of fan revolutions (DHW)
rpm/min
5.600
5.600
Minimum number of fan revolutions (CH)
rpm/min
1.800
1.800
Minimum number of fan revolutions (DHW)
rpm/min
1.800
1.800
Minimum number of fan revolutions with collective pressurised chimney (3CEP)
rpm/min
2.200
-
Mynute Green 30 C.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
n° - mm - mm
1 - 63 - 130
1 - 63 - 130
Diaphragm: number of holes - diameter of holes
n° - mm
1 - 6
1 - 4,5
Heating maximum gas capacity
Sm
3
/h
3,17
kg/h
2,33
DHW maximum gas capacity
Sm
3
/h
3,17
kg/h
2,33
Heating minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
DHW minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
Numbers of fan revolutions at slow start
rpm/min
3.700
3.700
Maximum number of fan revolutions (CH)
rpm/min
5.500
5.700
Maximum number of fan revolutions (DHW)
rpm/min
5.500
5.700
Minimum number of fan revolutions (CH)
rpm/min
1.400
1.400
Minimum number of fan revolutions (DHW)
rpm/min
1.400
1.400
Mynute Green 38 C.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
n° - mm - mm
1 - 63 - 140
1 - 63 - 140
Diaphragm: number of holes - diameter of holes
n° - mm
1 - 7
1 - 5
Heating maximum gas capacity
Sm
3
/h
3,17
kg/h
2,33
DHW maximum gas capacity
Sm
3
/h
4,02
kg/h
2,95
Heating minimum gas capacity
Sm
3
/h
0,74
kg/h
0,54
DHW minimum gas capacity
Sm
3
/h
0,74
kg/h
0,54
DESCRIPTION
Mynute Green
12 R.S.I. E
Mynute Green
15 R.S.I. E
Mynute Green
25 R.S.I. E
Mynute Green
35 R.S.I. E
Emission values at max. and min. rate of gas G20*
Maximum - Minimum CO s.a. less than
ppm
150 - 15
150 - 15
145 - 45
160 - 35
CO
2
%
9,0 - 9,5
9,0 - 9,5
9,0 - 9,5
9,0 - 9,5
NOx s.a. lower than
ppm
35 - 20
30 - 25
35 - 30
30 - 35
Flue gas temperature
°C
65 - 58
70 - 60
79 - 57
78 - 61
* Check performed with concentric pipe ø 60-100, length 0,85m - water temperature 80-60°C