ENGLISH
19
DESCRIPTION
Mynute Green
12 R.S.I. E
Mynute Green
15 R.S.I. E
Mynute Green
25 R.S.I. E
Mynute Green
35 R.S.I. E
Heating
Heat input
kW
12,00
15,00
25,00
34,60
kcal/h
10.320
12.900
21.500
29.756
Maximum heat output (80/60°C)
kW
11,75
14,64
24,50
33,67
kcal/h
10.103
12.590
21.070
28.953
Maximum heat output (50/30°C)
kW
12,71
15,75
26,25
36,71
kcal/h
10.929
13.545
22.575
31.571
Minimum heat input (**)
kW
2,50 - 3,50 (G31)
3,50
6,00
7,00
kcal/h
2.150 - 3.010 (G31)
3.010
5.160
6.020
Minimum heat output (80/60°C)
kW
2,44 - 3,42 (G31)
3,46
5,89
6,85
kcal/h
2.101 - 2.944 (G31)
2.977
5.067
5.888
Minimum heat output (50/30°C)
kW
2,70 - 3.75 (G31)
3,76
6,48
7,51
kcal/h
2.318 - 3.227 (G31)
3.230
5.573
6.459
Nominal Range Rated heat output (Qn)
kW
12,00
15,00
25,00
34,60
kcal/h
10.320
12.900
21.500
29.756
Minimum Range Rated heat output (Qm) kW
2,50 - 3,50 (G31)
3,50
6,00
7,00
kcal/h
2.150 - 3.010 (G31)
3.010
5.160
6.020
** = 6,0 kW with collective pressurised chimney (3CEP) - ONLY FOR 25 R.S.I.
Useful efficiency Pn max - Pn min (80°/60°)
%
97,9 - 97,7
(min 97,8 G31)
97,6 - 98,9
98 - 98,2
97,3 - 97,8
Useful efficiency 30% (47° return)
%
102,1
101,8
102,3
102,7
DESCRIPTION
Mynute Green 25 C.S.I. E Mynute Green 30 C.S.I. E
Mynute Green 38 C.S.I. E
Boiler dimensions
Height
mm
780
780
780
Width
mm
400
450
450
Depth of housing
mm
358
358
358
Boiler weight
kg
37
41
44
Flow rate (G20)
Air capacity
Nm
3/
h
31,237
37,361
35,395
44,362
Flue gas capacity
Nm
3
/h
33,744
40,371
38,404
48,134
Mass flow of flue gas (max-min)
gr/s
11,32 - 2,58
13,538 - 2,568
12,838-2,996 16,091-2,996
Flow rate (G31)
Air capacity
Nm
3/
h
31,485
38,102
36,288
45,481
Flue gas capacity
Nm
3
/h
33,416
39,266
37,451
46,939
Mass flow of flue gas (max-min)
gr/s
11,78 - 2,70
13,256 - 2,523
12,615-2,944 15,811-2,944
Fan performance
Residual head of boiler without pipes
Pa
180
105
105
Residual head of concentric pipes 0,85 m
Pa
45
40
25
Residual head of separate pipes 0,5 m
Pa
150
84
95
Max pressure allowed with pressurised collective chimney
Pa
50
-
-
Concentric flue gas discharge pipes
Diameter
mm
60-100
60-100
60-100
Maximum length
m
7,85
7,85
3,85
Drop due to insertion of a 45°/90° bend
m
1,3/1,6
1,3/1,6
1,3/1,6
Hole in wall (diameter)
mm
105
105
105
Concentric flue gas discharge pipes
Diameter
mm
80-125
80-125
80-125
Maximum length
m
14,85
14,85
10
Drop due to insertion of a 45°/90° bend
m
1/1,5
1/1,5
1/1,5
Hole in wall (diameter)
mm
130
130
130
Separate flue gas discharge pipes
Diameter
mm
80
80
80
Maximum length
m
36+36
30+30
30+30
Losses for a 45°/90° bend
m
1/1,5
1/1,5
1/1,5
Installation B23P–B53P
Diameter
mm
80
80
80
Maximum length of drainage pipe
m
60
47
45
NOx class
5
5
5
Emission values at max. and min. rate of gas G20*
Maximum - Minimum CO s.a. less than
ppm
145 - 45
130 - 12
200 - 30
CO
2
%
9,0 - 9,5
9,0 - 9,5
9,5 - 9,5
NOx s.a. lower than
ppm
35 - 30
30 - 25
40 - 25
Flue gas temperature
°C
79 - 57
77 - 59
74 - 61
* Check performed with concentric pipe ø 60-100, length 0,85m - water temperature 80-60°C
Содержание Mynute Green E C.S.I.
Страница 167: ...167 Mynute Green C S I E R S I E Mynute Green 25 C S I E Mynute Green 30 C S I E 38 C S I E 23 28 10 16 28 10 16...
Страница 168: ...168 Mynute Green C S I E R S I E Mynute Green 12 15 R S I E Mynute Green 25 R S I E 10 16 10 16 23...
Страница 192: ...Via Risorgimento 13 23900 Lecco LC Italy Cod 20095912 09 15 Ed 1...