26
ENGLISH
Multigas table
DESCRIPTION
Methane gas (G20)
Butane (G30)
Propane (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
80,58
70,69
Net Calorific Value
MJ/m
3
S
34,02
116,09
88
Supply nominal pressure
mbar
(mm W.C.
)
20
203,9
28-30
285,5-305,9
37
377,3
Supply minimum pressure
mbar
(mm W.C.
)
13,5
137,7
-
-
Mynute Boiler 28/60 B.A.I.
Burner (number of holes)
n°
14
14
14
Burner (diameter of holes)
mm
1,3
0,77
0,77
Heating maximum gas capacity
Sm
3
/h
3,28
kg/h
2,44
2,41
DHW maximum gas capacity
Sm
3
/h
3,28
kg/h
2,44
2,41
Heating minimum gas capacity
Sm
3
/h
1,48
kg/h
1,10
1,09
DHW minimum gas capacity
Sm
3
/h
1,04
kg/h
0,77
0,76
Maximum pressure downstream CH valve
mbar
11,70
27,80
35,60
mm W.C.
119,31
283,48
363,02
Maximum pressure downstream DHW valve
mbar
11,70
27,80
35,60
mm W.C.
119,31
283,48
363,02
Minimum pressure downstream CH valve
mbar
2,60
6,50
7,80
mm W.C.
26,51
66,28
79,54
Minimum pressure downstream DHW valve
mbar
1,40
2,80
4,10
mm W.C.
14,28
28,55
41,81
Mynute Boiler 24/45 B.S.I.
Burner (number of holes)
n°
12
12
12
Burner (diameter of holes)
mm
1,35
0,77
0,77
Heating maximum gas capacity
Sm
3
/h
2,73
kg/h
2,03
2,00
DHW maximum gas capacity
Sm
3
/h
2,73
kg/h
2,03
2,00
Heating minimum gas capacity
Sm
3
/h
1,34
kg/h
1,00
0,99
DHW minimum gas capacity
Sm
3
/h
1,04
kg/h
0,77
0,76
Maximum pressure downstream CH valve
mbar
9,80
27,40
35,70
mm W.C.
99,93
279,40
364,04
Maximum pressure downstream DHW valve
mbar
9,80
27,40
35,70
mm W.C.
99,93
279,40
364,04
Minimum pressure downstream CH valve
mbar
2,40
7,00
9,30
mm W.C.
24,47
71,38
94,83
Minimum pressure downstream DHW valve
mbar
1,50
4,20
5,50
mm W.C.
15,30
42,83
56,08
Mynute Boiler 28/60 B.S.I.
Burner (number of holes)
n°
14
14
14
Burner (diameter of holes)
mm
1,35
0,77
0,77
Heating maximum gas capacity
Sm
3
/h
3,19
kg/h
2,38
2,35
DHW maximum gas capacity
Sm
3
/h
3,19
kg/h
2,38
2,35
Heating minimum gas capacity
Sm
3
/h
1,34
kg/h
1,00
0,99
DHW minimum gas capacity
Sm
3
/h
1,11
kg/h
0,83
0,82
Maximum pressure downstream CH valve
mbar
10,20
27,50
35,70
mm W.C.
104,01
280,42
364,04
Maximum pressure downstream DHW valve
mbar
10,20
27,50
35,70
mm W.C.
104,01
280,42
364,04
Minimum pressure downstream CH valve
mbar
2,00
4,80
6,70
mm W.C.
20,39
48,95
68,32
Minimum pressure downstream DHW valve
mbar
1,40
3,20
4,70
mm W.C.
14,28
32,63
47,93