background image

30

EXCLUSIVE

9.2.1  ON

If 

ON

 is selected, the zone requests are met.

9.2.2  AUTO

If 

AUTO

  is  selected,  the  zone  requests  will  be  managed  based  on  a 

scheduled programme.

9.2.3  MANUAL

If 

MANUAL

 is selected, the zone requests will be managed based on the 

setpoint set by the user.

9.2.4  HEAT OFF

If 

HEAT OFF

 is selected, the zone requests will not be fulfilled.

NOTE:

  if  you  want  to  deactivate  the  zone  in  SUMMER  or  in  WINTER, 

you must select the pre-set season (SUMMER or WINTER in the BOILER 

menu) and set the zone concerned to OFF.

10  SET

With the 

SET

 function it is possible to configure the 

HEATING

 and 

HOT 

WATER

 setpoints.

To do this, it is necessary to highlight the desired entry using the 

“up”

 and 

“down”

 keys and then pressing 

“ok”

 to confirm the selection.

Pressing 

“back”

 takes you back to the initial screen without making any 

selection

.

SET

HEATING

HOT WATER

10.1  Heating

Press  the 

“up”

 and 

“down”

  keys  to  change  the  heating  setpoint  and 

confirm the selection by pressing 

“ok”

.

Press 

“back”

 to return to the 

SET

 screen without making any selection.

SET

HEATING

78,0

°C

When an outdoor temperature sensor is installed, the outlet temperature 

is automatically selected by the system, which quickly adjusts the ambient 

temperature according to the variations in the outdoor temperature. If you 

want to change the temperature, raising it or lowering it with respect to that 

automatically calculated by the electronic board, it is possible to change 

the HEATING setpoint selecting the desired comfort level within the range

 

(-5 

÷ 

+5).

The user is then asked to confirm the setpoint setting: select 

CONFIRM

 

or 

CANCEL

 using the 

“up”

 and 

“down”

 keys, and confirm the selection 

pressing 

“ok” 

.

Once the selection is confirmed, the display returns to the 

SET

 screen.

If the selection is cancelled or the 

“back”

 key is pressed you return to the 

previous 

SET

 screen.

SET

THE PARAMETER

WILL BE CHANGED

CONFIRM

CANCEL

CONFIRM OR DELETE 

SELECTION

 

10.2  Domestic hot water (only when storage tank with 

probe is connected)

Press the 

“up”

 and 

“down”

 keys to change the boiler’s domestic hot water 

setpoint. Press 

“ok”

 to confirm the selection.

Press 

“back”

 to return to the 

SET

 screen without making any selection.

SET

HOT WATER

58,0

°C

The user is then asked to confirm the setpoint setting: select 

CONFIRM 

or else 

CANCEL

 using the 

“up”

 and 

“down”

  keys  and  confirm  the 

confirmation with 

“ok”

.

Once the selection is confirmed, the display returns to the previous 

SET 

screen.

If the selection is cancelled or the 

“back”

 key is pressed you return to the 

SET

 screen

.

SET

THE PARAMETER

WILL BE CHANGED 

CONFIRM OR DELETE 

SELECTION

CONFIRM

CANCEL

11  INFO

The 

INFO

 function can be used to display a series of data regarding the 

system.

ATTENTION

 - The displayed data cannot be modified.

Press  the 

“up”

 and 

“down”

  keys  to  go  through  the  list  of  information 

available, in this order

:

 -

SCREED HEATER OPERATING HOURS

 -

FLOW PROBE

 -

RETURN PROBE

 -

DOMESTIC HOT WATER PROBE 

 -

FLUE GAS PROBE

 -

OUTDOOR TEMPERATURE SENSOR

 -

EXT T FOR THERMOREG

 -

FAN

 -

ZONE 1 DELIVERY

 -

ZONE 2 DELIVERY

 -

FLUE GAS PROBE OP. HOURS

 -

MAIN ZONE SET-POINT

 -

ZONE 1 SET-POINT

 -

ZONE 2 SET-POINT

 -

SYSTEM PRESSURE.

The 

“ok”

 key is inactive.

The 

“back”

 key allows you to return to the initial screen.

In the absence of additional zones or if the screed heater function is not 

operating, the relative information will not be displayed.

12  MENU

Using the MENU it is possible to access the configuration of the SETTINGS 

and the TIME SCHEDULE (available only if the timer is enabled (POR=1).

To do this, it is necessary to highlight the desired entry using the 

“up”

 and 

“down”

 keys and then pressing 

“ok”

 to confirm the selection.

Pressing 

“back”

 takes you back to the initial screen without making any 

selection

.

Содержание EXCLUSIVE R

Страница 1: ...EXCLUSIVE R Installer and user manual RO MANUAL DE INSTALARE SI UTILIZARE EN ES INSTALLER AND USER MANUAL MANUAL DE INSTALACI N Y USO...

Страница 2: ...o Warning This instructions manual contains data and information for both the user and the installer Specifically note that the user for the use of the appliance must refer to chapters Warnings and sa...

Страница 3: ...qualified personnel a a Any technical or cleaning operation is forbidden before disconnecting the appliance from the main power supply by turning the system s main switch to OFF and the main switch o...

Страница 4: ...ion of the instrument for the combustion analysis check In fig 6b is shown a sample drawing where the distances between boiler and cabinet niche were obtained using a 300mm length tool Longer lengths...

Страница 5: ...60 100 mm vertical 11 m 9 m 1 3 m 1 6 m Concentric pipe 80 125 mm 25 m 20 m 1 m 1 5 m Twin pipe 80 mm 70 70 m 35 35 m 1 m 1 5 m b b Straight length means with terminals and joints but without bends b...

Страница 6: ...ons open the caps of the lower A automatic air vent valve by two or three turns to allow a continuous venting of the air leave the plug of the valve A open make sure the cold water inlet tap is open o...

Страница 7: ...g disabling the key lock function is achieved by pressing the button A for more than 10 seconds During this step all of the LEDs C will flash for 1 second 3 11 6 Changing the operating mode In normal...

Страница 8: ...l as the outdoor temperature if available On the left and right sides are displayed the icons indicating the status of the system their meaning is as follows Pressing the keys up and down it is possib...

Страница 9: ...T 80 5 C AT 45 C BT INSTALLER CHANGE NAME INSTALLER PI PROPORTIONAL 5 0 99 SERVICE Only mixing zones with ACTUATION BE16 PI INTEGRAL 10 0 99 SERVICE Only mixing zones with ACTUATION BE16 VALVE RUN 120...

Страница 10: ...y if managed by the control board THERMOREGULATION INSTALLER CLIMATIC CURVES MAIN MAIN ZONE1 ZONE2 INSTALLER FIXED SET POINT 80 5 C AT 45 C BT MIN CH SET MAX CH SET INSTALLER If EXTERNAL PROBE NOT con...

Страница 11: ...NT 50 C 37 5 C 60 C INSTALLER Only if HEAT PUMP enabled to DHW TANK FROST PROTECT 7 C 0 C 100 C SERVICE Only if HEAT PUMP enabled to DHW TANK FR PROT OFFSET 5 C 1 C 20 C SERVICE Only if HEAT PUMP enab...

Страница 12: ...C INSTALLER MIN EMERG OUT T 10 C 20 C 10 C INSTALLER BOILER INTEGR DELAY 30min 1min 240min SERVICE HP INTEGR DELAY 30min 1min 240min SERVICE BOILER WAITING 2min 1min 60min SERVICE HEAT PUMP WAITING 2m...

Страница 13: ...orrectly that conditions for regular maintenance are guaranteed if the boiler is placed inside or between items of furniture the seal of the fuel adduction system that the fuel flow rate corresponds t...

Страница 14: ...ER OFF CH 3MIN RESET TIMERS CH This parameter allows you to reset the REDUCED HEATING MAXIMUM OUTPUT TIMING during which the speed of the fan is limited to 75 of the maximum heating output that has be...

Страница 15: ...ING NAME This parameter allows you to attribute a specific name to the heating zone POR This parameter allows you to enable the central heating programming timing for the zone concerned if the heat re...

Страница 16: ...depends on the type of heat request In any case the thermoregulation algorithm will not directly use the outdoor temperature but rather a calculated outdoor temperature that takes into account the bui...

Страница 17: ...16 C that can vary within the range 5 5 5 3 First commissioning Position the system s master switch to the on position Open the gas tap to allow fuel to flow Adjust the room thermostat to the desired...

Страница 18: ...ected When an outdoor temperature sensor is installed the outlet temperature is automatically selected by the system which quickly adjusts the ambient temperature according to the variations in the ou...

Страница 19: ...he up and down keys and confirm the selection to deactivate the function INSTALLER SCREED HEATING FUNZIONE GIORNALIERA DEACTIVATE FUNCTION ACTIVATE FUNCTION The screed heating function when active is...

Страница 20: ...from the cover of the instrument panel to access the electrical components AKM0x X17 X14 1 1 X12 X23 X16 X2 X21 X8 X13 X19 X9 X25 X11 X18 X22 1 1 1 1 1 1 1 1 6 1 5 12 10 4 3 5 4 6 5 6 X15 X1 X4 X6 1 3...

Страница 21: ...pplied with the settings indicated in the multigas table It is nevertheless possible according to the system requirements or the regional regulations on the combustion gas emission limits to set that...

Страница 22: ...k button it is possible to return to the main screen where a fault is signalled by this flashing icon 18 05 2013 12 17 MENU INFO SET 42 C 1 3 bar FRI PLANT HOT WATER TEMPERATURE STATE The user can ret...

Страница 23: ...0 5 sec on 0 5 off definitive E030 fan fault ON definitive E040 water transducer load the system ON definitive E041 water transducer load the system flashing 0 5 sec on 0 5 off transitional E042 water...

Страница 24: ...to OFF set the system s main switch to off close the fuel and water taps of the heating and domestic hot water system In this case the anti freeze and anti blocking systems are deactivated Drain the h...

Страница 25: ...REC10 MASTER and finish the operatione NEW to set a new system configuration restoring the factory setting of the parameters NEW FROM AKM SELECT THE TYPE OF CONFIGURATION ON OFF Closing position 5 20...

Страница 26: ...TI ZONE CONTROLLER REC10 V01 26 PRESS ANY KEY TO CONTINUE SELECT THE TYPE OF CONFIGURATION NEW FROM AKM 5 23 Replacing the AKM01 board The configuration operations should be carried out by professiona...

Страница 27: ...umption at maximum and minimum output checking the position of the ignition flame detection glowplug checking the gas failure safety device b b After carrying out the maintenance operations the analys...

Страница 28: ...ING function enabled If a heating request from the main zone is in progress the icon will be flashing This icon indicates that the circuit for domestic hot water production is enabled When a domestic...

Страница 29: ...ing ok to confirm the selection Pressing back takes you back to the initial screen without making any selection BOILER STATE MAIN ZONE 9 1 Boiler This function can be selected in order to set the boil...

Страница 30: ...n If the selection is cancelled or the back key is pressed you return to the previous SET screen SET THE PARAMETER WILL BE CHANGED CONFIRM CANCEL CONFIRM OR DELETE SELECTION 10 2 Domestic hot water on...

Страница 31: ...st the current time is replaced with the boiler flow temperature and turns on the icon concerning the type of request in progress A message for the system efficiency level can be displayed in the top...

Страница 32: ...D THURSDAY MODIFY DELETE COPY 07 30 11 30 18 00 END 08 30 13 30 22 30 SELECT OPTION Press the up and down keys to select the desired time band and press ok to confirm the selection START MAIN THURSDAY...

Страница 33: ...O MODIFY In order to confirm that the operation has been completed successfully the display will show the list of days to which the scheduled programme has been copied MAIN SCHEDULE OF THURSDAY WILL B...

Страница 34: ...h check the system flashing 0 5 sec on 0 5 off transitional boiler board communication lost ON transitional BUS 485 communication lost ON transitional List of combustion faults ERROR CODE ERROR MESSAG...

Страница 35: ...REC10 after which the machine must be disconnected from the power supply to reset the number of attempts available b b Request the intervention of the Technical Assistance Centre E020 LIMIT THERMOSTAT...

Страница 36: ...6 5 107 8 103 9 105 8 105 9 107 4 103 2 101 0 Useful efficiency Pn max 30 30 return 109 8 105 8 109 3 106 6 Efficiency at average P Range Rated 80 60 98 0 97 8 Efficiency at average P Range Rated 30 3...

Страница 37: ...20 G31 G20 G31 Maximum CO s a less than p p m 140 150 220 220 CO2 9 2 10 2 9 0 10 0 NOx s a lower than p p m 40 60 40 30 T flue gases C 63 64 65 70 Minimum CO s a less than p p m 10 15 20 40 CO2 9 1 1...

Страница 38: ...fan rotations rpm 1 500 1 900 Minimum number of DHW fan rotations rpm 1 500 1 900 b b DHW functions refer only if a storage tank is connected accessory available on request Parameter Symbol EXCLUSIVE...

Страница 39: ...ner 9 Conveyor 10 Fan 11 Mixer 12 Ignition transformer 13 Flue gas exhaust 14 Degassing unit pipe 15 Flue gas probe 16 Upper air vent valve 17 Limit thermostat 18 NTC delivery probe 19 Flame ignition...

Страница 40: ...bianco TBT OT SE TBT TA A B REC X11 X14 X25 M20 grigio grigio 1 10 viola viola rosso rosso nero alim blu sign marrone MOD 1 3 X19 T P 4 3 TBOL 1112 SBOL 6 1 X1 marrone blu 2 1 3 5 4 rosa blu P N L F 3...

Страница 41: ...at exchanger 13 NTC delivery probe 14 Limit thermostat 15 Upper air vent valve 16 Air water separator 17 Water tank available by request 3 16 15 A B 1 C D 11 12 13 10 7 6 5 3 2 4 14 8 9 E F TA Room th...

Страница 42: ...W pump modulation area graphic 1 setted to 7 metre circulator graphic 2 setted to 5 metre circulator graphic 3 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 0 100 200 300 400 500 600 700 80...

Страница 43: ...43 EXCLUSIVE 5 A condensate drain B water gas 25R 35R C 275 350 A B C 6a 6b distances in mm measured in mm 6 Indoor installation Outdoor installation in a partially protected place...

Страница 44: ...sensor 13 14 OT Open therm 15 16 SBOL Water tank probe 17 18 X1 Not used 19 20 X2 Not used 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 A B TA TBOL TBT SE OT SBOL X1 X2 M20 D Voltage free contac...

Страница 45: ...IN PIPE 80mm 15 90 bend flange installed as standard A A C B COAXIAL PIPE 80 125mm flange installed as standard A A C B 90 bend flange installed as standard C B 90 bend A A adaptor flange installed as...

Страница 46: ...50 60 70 80 90 20 15 10 5 0 5 10 15 20 25 30 D A E CURVE DI TERMOREGOLAZIONE Temperatura esterna C Temperatura di mandata C 20 30 40 50 60 70 80 90 100 20 0 2 0 4 0 6 0 8 1 0 1 5 2 0 2 5 3 0 T80 T45 1...

Страница 47: ...25 130 135 140 145 150 155 160 165 170 175 Lunghezza tubo scarico fumi m Lunghezza tubo aspirazione aria m CaldaiaExclusive 25C n lunghezza massimatubi 80 mm EXCLUSIVE 25R flue gas pipe length m air s...

Страница 48: ...information contained in this manual at any time and without prior notice Consumers statutory rights are not affected Cod 20097753 04 15 Ed 0 Cod 20127998 07 17 Ed 2 RANGE RATED EN 483 The max CH inp...

Отзывы: