2 | Installation

19

1

Display

2

On- Off key

3

Quick function keys

When the door is closed, you can activate the quick functions, such as

choosing the operating mode and setting the desired temperature.

Ensure that the door is fully closed. If this is not the case, the

external keys will not work.

Function keys with door closed

It switches the device on and off
It increases or decreases the selected parameter value

Select required ventilation speed: minimum, medium,

maximum or automatic
It activates the Quiet mode
It activates the Cooling mode
It activates the Heating mode
It activates the Dehumidification mode
It activates the Smart mode
It enables the Maximum Power function

1

Door

2

Advanced function keys

When the door is open, you can access the advanced functions, e.g.

time scheduling and motor-driven deflector settings.

Function keys with door open

It activates and deactivates the automatic movement of

the horizontal deflector or stops it in a specific position
Function not available
It selects the Ventilation operating mode
It activates the Sleep function
Function not available
It enables the Health Air Flow function
If pressed at the same time, they lock and unlock the

remote control keys

Not available
Switch on or off the unit display
It gives access to current time change settings
It gives access to Timer settings
It increases or decreases the selected parameter value

It allows to change the remote control transmission

channel A - b with the unit (recommended to select A =

factory setting)
It confirms settings
It switches the temperature scale from Celsius to

Fahrenheit and vice versa

Remote control display

The remote control display shows the settings as changed by the user

and the detected weather conditions.
The display is divided into uniform areas according to function type.

Содержание 20171580

Страница 1: ...Installer manual BREVA IN EN...

Страница 2: ...ion that we have deemed necessary for the device s correct and easy installation Thank you again and keep up the good work BERETTA Compliance BREVA IN heat pumps are compliant with the following Europ...

Страница 3: ...ng into service 3 3 Temporary shutdown 3 4 Stop for an extended period of time 3 5 Ordinary maintenance 3 6 Extraordinary maintenance 3 7 Alarms The following symbols are used on the product The R32 r...

Страница 4: ...nt of refrigerant contained within the installed system must be indicated This information can be found on the unit technical data plate This unit contains fluorinated greenhouse gases covered by the...

Страница 5: ...1 General information 5...

Страница 6: ...ins the device s technical and performance data The tampering removal or absence of the identification plates will not allow the product to be properly identified by its serial number 1 6 Layout 1 Air...

Страница 7: ...nimum speed Rpm 850 900 750 800 Super minimum speed Rpm 650 650 610 700 Cooling sound levels Superminimum sound pressure dB A 20 21 28 30 Minimum sound pressure dB A 28 29 35 37 Medium sound pressure...

Страница 8: ...nd for the Technical Service in English user instruction booklet in Italian user instruction booklet in English Warranty Spare parts labels contact sheets It is also supplied as kit Remote control no...

Страница 9: ...rant charge of the system given by the sum of the factory charge of the outdoor unit and if appicable the additional charge The amount of refrigerant charged inside the unit refer to the INSTALLATION...

Страница 10: ...stem is compliant with the applicable regulations and has been installed by qualified professionals In the event of a replacement the system must be inspected by the designer or by another competent p...

Страница 11: ...water level Drilling into the wall A Inner side B Outer side 1 Hole protective insert supplied 2 Plastic tube drill the through hole into the wall keep a downward inclination toward the external side...

Страница 12: ...king bracket to space the unit lower side from the metallic support If there is a connection box use one of the polystyrene protections from the packaging After performing the connections hook the uni...

Страница 13: ...Outer side 1 Plastic tube 2 Connections drill the through hole into the wall keep a downward inclination toward the external side insert a plastic tube in the hole in order to protect the connections...

Страница 14: ...e mm Inches Nm 6 35 1 4 18 9 52 3 8 42 12 7 1 2 55 15 88 5 8 60 Pipe A mm Inches mm 6 35 1 4 17 9 52 3 8 22 12 7 1 2 26 15 88 5 8 29 bring line ends with flare connection close to their coupling on th...

Страница 15: ...sate discharge connection is provided with a tray that collects condensate generated during the cooling operation which must be conveyed into a suitable place for discharge Sizes and position of the d...

Страница 16: ...sh filters open the front panel take out the mesh filter by grabbing the relevant fins pour water into the condensate tray check that it flows out correctly through the drainage pipe reposition the fi...

Страница 17: ...letely wired and only requires a connection to the outdoor unit position the system s main switch in the OFF position To access the terminal board 1 Electric panel access panel 2 Connection cable 3 Te...

Страница 18: ...t take anti static precautions in case of weather conditions where humidity is less than 40 Electric connections shall be made in compliance with national regulations Avoid placing the connection cabl...

Страница 19: ...ven deflector settings Function keys with door open It activates and deactivates the automatic movement of the horizontal deflector or stops it in a specific position Function not available It selects...

Страница 20: ...er settings Timer setting value or current time display Switch on timer enabled Icon timer off eps Switch off timer enabled Motor driven deflector settings Horizontal deflector position Function not a...

Страница 21: ...t switches off and cannot be activated via external control if contact CN51 is closed the unit can be activated via external control OFF disabled if contact CN51 is open the unit switches off but it c...

Страница 22: ...ssed down with a pointy object until a double acoustic signal is emitted the air conditioner starts in cooling mode with high ventilation speed and active air deflector To switch off press the emergen...

Страница 23: ...a sponge or soft cloth with water and soap to wash once cleaning is over dry surfaces with care Do not use water at a temperature that is higher than 40 C powder or abrasive detergents solvents and br...

Страница 24: ...the system s main switch in the OFF position disconnect the cooling pipes disconnect the condensate discharge disconnect the electric connections push up and release the unit from its metallic suppor...

Страница 25: ...secutive interventions in 20 minutes the unit resets after problem resolution F14 17 4 way valve malfunction The alarm activates 5 minutes after the unit start The alarm activates when in Heating mode...

Отзывы: