2 | Installation
13
1
Gas line connection
2
Liquid line connection
model
9000
12000
18000
24000
Connections
Liquid line
connection
Inches
1/4
1/4
1/4
1/4
Gas line connection
Inches
3/8
3/8
1/2
1/2
Liquid line
connection
mm
6,35
6,35
6,35
6,35
Gas line connection
mm
9,52
9,52
12,70
12,70
Connection outlet directions are indicated below.
In case of connection in directions A:
– remove the relevant pre-trimmed part on the cover cabinet
In case of connection in directions B:
MODEL 9000-12000
MODEL 18000
MODEL 24000
– mark the through hole as shown in the illustration
A
Inner side
B
Outer side
1
Plastic tube
2
Connections
– drill the through hole into the wall
– keep a downward inclination toward the external side
– insert a plastic tube in the hole in order to protect the
connections
– introduce the supplied hole protection insert on the internal side
of the wall
– seal with stucco
For indications concerning distances and differences in height of
connection pipes, refer to the matching outdoor unit manual.
Use clean hoses. Make sure the inside is free of dust, residues,
water.
Avoid the entry of uncondensable gases (air) in the circuit,
otherwise, with the unit in operation, high pressures with the risk of
damages might ensue.
Use copper pipes for cooling systems.
It is forbidden to use second-hand cooling lines since their flare
connection seal is not guaranteed.