HYDRONIC UNIT LE B

56

Function 

Parameter Description 

Value range 

Default 

value

 Set 

value

 

Min 

Max 

Min heating water 

temperature

120

Code used to select the minimum outdoor temperature of the heating climate curve. 20°C

60°C

35°C

Max heating water 

temperature

121

Code used to select the maximum outdoor temperature of the heating climate curve. 20°C

60°C

55°C

Max outdoor air 

temperature in cooling 

mode

122

Code used to select the maximum outdoor temperature of the cooling climate curve, 

which depends on the country where the system is installed.

24°C

46°C

40°C

Min outdoor air 

temperature in cooling 

mode

123

Code used to select the minimum outdoor temperature of the climate curve in 

cooling mode

0°C

30°C

20°C

Min cooling water 

temperature

124

Code used to select the minimum water temperature of the climate curve in cooling 

mode.

4°C

20°C

4°C

Max cooling water 

temperature

125

Code used to select the maximum water temperature of the climate curve in cooling 

mode.

4°C

20°C

15°C

Outdoor air temp. 

sensor GMC

126

Code used to indicate whether the GMC outdoor air temperature sensor is installed 

or not

1. GMC external air temperature sensor installed

2. GMC external air temperature sensor not installed

1

2

2

TO sensor value

127

The code indicates the outdoor air temperature value measured by the TO sensor

-

-

-

Lock

TE sensor value

128

The code indicates the refrigerant temperature value measured by the TE sensor

-

-

-

Lock

TS sensor value

129

The code indicates the refrigerant temperature value measured by the TS sensor

-

-

-

Lock

TD sensor value

130

The code indicates the refrigerant temperature value measured by the TD sensor

-

-

-

Lock

Operating mode

131

The code indicates the current operating mode of the Heat Pump

1. Off

2. Cooling

3. Heating

4. Faulty

5. Defrost

-

-

-

Lock

Compressor max 

frequency

132

The code indicates the maximum frequency of the compressor calculated by the 

GMC control board

-

-

-

Lock

Requested frequency

133

The code indicates the frequency requested by the system control

-

-

-

Lock

Actual frequency

134

The code indicates the actual compressor frequency

-

-

-

Lock

Compressor run time

135

The code indicates the compressor working hours

-

-

-

Lock

Capacity

136

The code indicates the nominal capacity of the heat pump (kW)

-

-

-

Lock

EWT sensor value

137

N.A.

-

-

-

Lock

LWT sensor value

138

The code indicates the temperature of the water leaving the heat pump read by the 

LWT sensor

-

-

-

Lock

TR sensor value

139

The code indicates the temperature of the refrigerant measured by the TR sensor

-

-

-

Lock

Operating mode

140

The code indicates the operating mode requested by the System Control

0. Off

1. Stand by

2. Cooling

3. Heating

4. N.A.

5. N.A.

6. Nominal Heating

7. Nominal cooling

8. Antifreeze protection

9. Defrost

10. High temperature protection

11. Compressor start waiting

12. System error

13. Advanced freeze protection

-

-

-

Lock

Errors

141

The code lists all the error codes detected by the outdoor unit. If there are no errors, 

no code is displayed.

-

-

-

Lock

Gmc software version

142

The code indicates the GMC software release

-

-

-

Lock

Gmc software version

143

The code indicates the GMC Software Version

-

-

-

Lock

Water pump run time

144

The code indicates how long the water pump has been operating.

-

-

-

Lock

Current water set 

point

145

The code indicates the current water set point set by the system control.

-

-

-

Lock

Clean contact off

146

Code used to set the various SWITCHING OFF logics

1. Standard OFF

2. Controlled OFF cycle (only if the Heat Pump is controlled by clean contact)

1

2

1

Alarm/ ambient air 

temperature reached

147

Code used to select the output connected to PIN 5 of the terminal board

1. Alarm signal

2. Signal that the air temperature set point has been reached

1

2

1

Содержание 20103221

Страница 1: ...1 HYDRONIC UNIT Instructions for installation Instructions d installation LE4B LE6B LE8B LE12B EN Instructions for installation FR Instructions d installation...

Страница 2: ...e manuel a le but de vous fournir les informations n cessaires pour une installation simple et correcte sans rien vouloir ajouter votre comp tence et votre capacit technique Nous vous remercions de vo...

Страница 3: ...34 Electrical wiring 34 Control panel 39 Charging the system 40 Adjustment of the circulation pump 41 TECHNICAL ASSISTANCE CENTRE First commissioning 42 Switching off for lengthy periods 43 System dr...

Страница 4: ...ique 27 INSTALLATEUR R ception de l appareil 28 Manutention et transport 29 Acc s aux parties internes 29 Installation 30 Raccordements hydrauliques 32 Raccordement vacuation de la condensation 34 Bra...

Страница 5: ...contain refrigerant gases handle carefully to avoid damaging the gas circuit G N RAL CONSEILS G N RAUX Apr s avoir enlev l emballage s assurer que le contenu est en bon tat et qu il ne manque rien En...

Страница 6: ...exclusivement par un personnel qualifi L appareil contient du gaz r frig rant prendre donc toutes les pr cautions qui s imposent pour ne pas ab mer le cir cuit du gaz R GLES FONDAMENTALES DE S CURIT...

Страница 7: ...ce op eration difficult DESCRIPTION Hydronic Unit LE B L appareil comprend Contr le DC INVERSEUR modulation PAM et PWM qui permet au compresseur d avoir une modulation continue de 30 120 tout en garan...

Страница 8: ...mp 5 Cap to release pump seizure 6 Flow meter 7 Expansion tank 1 Purgeur d air 2 Sonde de temp rature 3 Vanne de s curit sortie 1 2 4 Pompe de circulation 5 Bouchon de d blocage pompe suite au grippag...

Страница 9: ...9 kW 1 10 1 58 1 96 3 46 EER 9 3 02 3 2 98 2 96 ESEER 9 4 36 4 51 4 15 4 22 Generalities Sound pressure in heating mode dB A 42 42 44 47 Sound pressure in cooling mode dB A 44 44 45 48 Compressor ROT...

Страница 10: ...R 9 3 02 3 2 98 2 96 ESEER 9 4 36 4 51 4 15 4 22 Donn es g n rales Niveau de pression acoustique en chauffage 1 dB A 42 42 44 47 Niveau de pression acoustique en climatisation dB A 44 44 45 48 Compres...

Страница 11: ...6 03 7 75 6 46 15 75 Annual consumption Consommation annuelle kW h 4 148 5 927 5 381 12 620 Warm zone Low temperature 30 35 C Zone chaude Basse temp rature 30 35 C s 201 194 163 171 SCOP 5 09 4 92 4 1...

Страница 12: ...chaude sanitaire s obtient avec une temp rature de l air ext rieur non sup rieure 30 C Pour une temp rature de l air ext rieur sup rieure 30 C la production de l eau chaude sanitaire peut tre limit e...

Страница 13: ...ide kg 57 61 69 104 A mm 908 B mm 821 1363 C mm 326 D mm 350 E mm 87 174 F mm 356 640 G mm 466 750 H mm 40 44 L mm 60 69 600 154 154 430 400 363 37 1 2 3 600 154 154 430 400 363 37 1 2 3 75 65 B 8 B 1...

Страница 14: ...ey A Brown C Black V Violet B Blue W White Y G Yellow Green WIRING DIAGRAMS C blage du fabricant C blage de l installateur CM Moteur compresseur FM Moteur du ventilateur RV Vanne d inversion 4 voies T...

Страница 15: ...lve motor R Reactor F Fuse FL Filter R Red Y Yellow O Orange A Brown C Black V Violet B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur CM Moteur compresseur FM Moteur du...

Страница 16: ...S Domestic water input SV Three way domestic water valve R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur LWT Sonde sortie...

Страница 17: ...E 4 B CONTR LE R1 Resistance T Transformer F Fuse R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White V Violet Y G Yellow Green R1 R sistance T Transformateur F Fusible R Rouge Y Jaune O Ora...

Страница 18: ...lve motor R Reactor F Fuse FL Filter R Red Y Yellow O Orange A Brown C Black V Violet B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur CM Moteur compresseur FM Moteur du...

Страница 19: ...S Domestic water input SV Three way domestic water valve R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur LWT Sonde sortie...

Страница 20: ...E 6 B CONTR LE R1 Resistance T Transformer F Fuse R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White V Violet Y G Yellow Green R1 R sistance T Transformateur F Fusible R Rouge Y Jaune O Ora...

Страница 21: ...lve motor R Reactor F Fuse FL Filter R Red Y Yellow O Orange A Brown C Black V Violet B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur CM Moteur compresseur FM Moteur du...

Страница 22: ...S Domestic water input SV Three way domestic water valve R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur LWT Sonde sortie...

Страница 23: ...E 8 B CONTR LE R1 Resistance T Transformer F Fuse R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White V Violet Y G Yellow Green R1 R sistance T Transformateur F Fusible R Rouge Y Jaune O Ora...

Страница 24: ...motor R Reactor F Fuse R Red Y Yellow O Orange A Brown C Black P Pink V Violet B Blue W White G Grey Y G Yellow Green C blage du fabricant C blage de l installateur CM Moteur compresseur FM Moteur du...

Страница 25: ...IS Domestic water input SV Three way domestic water valve R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White Y G Yellow Green C blage du fabricant C blage de l installateur LWT Sonde sortie...

Страница 26: ...E 12 B CONTR LE R1 Resistance T Transformer F Fuse R Red Y Yellow O Orange A Brown C Black G Grey B Blue W White V Violet Y G Yellow Green R1 R sistance T Transformateur F Fusible R Rouge Y Jaune O Or...

Страница 27: ...Silencer 9 TO sensor 10 Heat exchanger 11 TE sensor 12 Distributor 13 Electronic expansion valve 14 TR sensor 15 Plate heat exchanger 16 LWT sensor 1 Compresseur rotatif 2 Accumulateur de liquide 3 FI...

Страница 28: ...he supplied accessories are inside the electrical panel INSTALLATEUR R CEPTION DE L APPAREIL Avertissements pr liminaires N enlever l emballage qu apr s avoir positionn l appareil sur le lieu d instal...

Страница 29: ...weight of the appliance ACCESS TO INNER PARTS Loosen the fixing screws Remove the access panel MANUTENTION ET TRANSPORT La manutention doit tre effectu e par un personnel qualifi quip comme il se doit...

Страница 30: ...w INSTALLATION Avertissements pr liminaires Le lieu d installation de l appareil doit tre d fini par le concepteur de l installation ou par une personne comp tente en la mati re et doit tenir compte d...

Страница 31: ...HYDRONIC UNIT LE B 31 150 500 1000 1000 150 300 300 300 200 1000 300 200 300 1000 1000 1500 2000 200 300 150 200 150 300 500 1000 150...

Страница 32: ...Avertissements pr liminaires L installateur est charg de choisir et d installer les composants Il doit travailler selon les r gles de la bonne technique et se conformer la l gislation en vigueur S as...

Страница 33: ...x endroits les plus bas du circuit 6 Vanne de purge aux endroits les plus hauts du circuit 7 Vanne 3 voies 8 Ballon d eau chaude sanitaire 9 Installation interne 10 Raccord de drainage A B C A B C 1 1...

Страница 34: ...h a maximum phase unbalance of 3 just for the three phase versions RACCORDEMENT VACUATION DE LA CONDENSATION Pr voir de soulever l appareil par rapport au sol 20 mm sans acheminement de la condensatio...

Страница 35: ...his manual Il faut obligatoirement Un interrupteur magn tothermique omnipolaire un sectionneur de ligne pouvant tre cadenass conforme aux Normes CEI EN ouverture des contacts d au moins 3 mm avec un p...

Страница 36: ...les de bonnes pratiques et la l gislation en vigueur Example of installation Exemple d installation connector connecteur RS 485 The ferrite must be installed as close as possible to the LEI board Inse...

Страница 37: ...n contact ouvert Chauffage contact ferm S3 Normal contact ouvert Eco contact ferm 1 Vanne 3 voies uniquement N 10 pour mod les ressort 18 N Alimentation 10 Signal 2 Demande source de chaleur compl men...

Страница 38: ...rter diagnostics board 12 B B LED GMC position Diagnostic board C Installation terminal strip D Cable holder E Strain relief Legende A Positie 4 leds diagnosefunctie kaart inverter 12 B B Positie led...

Страница 39: ...xing holes 2 Terminal board 3 Hole for connections 1 2 3 1 1 Trous pour la fixation 2 Bornier 3 Trou pour passage connexions PANNEAU DE COMMANDE Le panneau de commandes permet de faire tous les r glag...

Страница 40: ...NT DE L INSTALLATION Avertissements pr liminaires Il est interdit d ouvrir les volets d acc s et d effectuer toute intervention technique ou de nettoyage avant d avoir d branch l appareil en mettant l...

Страница 41: ...ce Modello 12 B The circulation pump features an interface that allows the head to be adjusted in 6 levels and 2 operating modes The factory setting is CP3 For any change in the factory settings pleas...

Страница 42: ...the specific model SERVICE TECHNIQUE APR S VENTE PREMI RE MISE EN SERVICE Avertissements pr liminaires La premi re mise en service de l appareil doit tre effectu e par le Service Technique Apr s vente...

Страница 43: ...f ARR T PENDANT DE LONGUES P RIODES Avertissements pr liminaires D sactiver l appareil uniquement partir du panneau de commande Si l appareil reste teint pendant l hiver des temp ratures ambiantes inf...

Страница 44: ...l ac tyl ne ou d autres gaz inflammables ou nocifs dans le circuit frigorifique car cela risque de provoquer une explosion Les conditions de fonctionnement autres que celles nominales peuvent donner...

Страница 45: ...efroidissement qui dans les conditions de fonctionnement nominales de l appareil doivent tre comprises respectivement entre 5 et 10 C dans les r frig rateurs et entre 4 et 8 C dans les pompes chaleur...

Страница 46: ...p rature actuellement s lectionn e ou fait d marrer le programme horaire Touche fl ch e en haut Augmente la temp rature ou la num rotation des l ments s lectionn s sur l afficheur en saisissant les pa...

Страница 47: ...ction 31 Domestic water supply 32 Not used 1 2 4 5 6 7 8 9 10 Symboles 1 Non Utilis 2 Non Utilis 3 Syst me teint 4 Temp rature air int rieur de la pi ce 5 ZONE 6 Non utilis 7 Mode Climatisation 8 Heur...

Страница 48: ...ters FONCTIONS R glage de la date et de l heure courante Le r glage de la date et de l heure est n cessaire lors de la premi re utilisation Appuyer sur la touche D H M R GLER L HEURE Le param tre s le...

Страница 49: ...nel is reset to the default values Mode de configuration installateur Pour acc der Appuyer en m me temps sur la touche Zone et sur la touche Bloquer pendant 3 secondes sans les rel cher Le num ro du p...

Страница 50: ...use fortuite Attendre au moins 10 minutes avant de r tablir les conditions de mise en marche Si l anomalie se r p te il faut contr ler soigneusement les composants de l appareil Avant de remettre l ap...

Страница 51: ...error Compressor breakdown UNIQUEMENT POUR LES MOD LES HYDRONIC UNIT LE 12 B Dans ces mod les les anomalies sont signal es travers des indicateurs situ s sur la carte de l inverseur et sur le panneau...

Страница 52: ...0 Outdoor temperature 11 Lock Outdoor Temperature measured by the sensor C 30 C 90 C Outdoor temperature GMC 12 Lock Outdoor temperature read by the GMC board C 20 C 65 C Room sensor temperature adjus...

Страница 53: ...ure ext rieure mesur e par le capteur C 30 C 90 C Temp rature ext rieure GMC 12 Lock Temp rature ext rieure lue par la carte GMC C 20 C 65 C Adaptation temp rature capteur ambiant 13 Correction de la...

Страница 54: ...ource required for ACS when External Air Temperature temperature set with code 148 2 Humidity control 1 2 2 Frost Delta set point 109 Code used to set the frost set point delta used by the antifreeze...

Страница 55: ...de l air ext rieur est inf rieure la temp rature configur e avec le code 148 2 Contr le de l humidit 1 2 2 Delta point de consigne gel 109 Code utilis pour configurer le point de consigne delta gel a...

Страница 56: ...ff 2 Cooling 3 Heating 4 Faulty 5 Defrost Lock Compressor max frequency 132 The code indicates the maximum frequency of the compressor calculated by the GMC control board Lock Requested frequency 133...

Страница 57: ...haleur 1 teint 2 Climatisation 3 Chauffage 4 Panne 5 D givrage Lock Fr quence max compresseur 132 Ce code indique la fr quence maximum du compresseur calcul e par la carte centrale GMC Lock Fr quence...

Страница 58: ...parameter 148 0 Always active 1 On Off depending by actual room temperature vs room temperature set point same hysteresis of the thermostat function If the command is not installed or the room sensor...

Страница 59: ...la temp rature ambiante r elle par rapport au point de consigne de la temp rature ambiante m me hyst r sis que la fonction Thermostat Si la commande n est pas install e ou que le capteur ambiant n est...

Страница 60: ...me without prior notice with the intention of improving the products This document cannot be considered a contract in relation to third parties Beretta beh lt sich das Recht vor die in diesem Handbuch...