Copyright © BEP Marine Limited, All rights reserved
Product version: DCM3.2
Page 18
Date: 12/05/05
Voltage 1 calibration
Adjust this setting to actual battery
Voltage. To calibrate
Up/Dn to select value, 0.01V steps
Range: 0-32V
Refer to page 9
Voltage 2 calibration
As per Voltage calibration 1
Voltage 3 calibration
As per Voltage calibration 1
Low and High Amp calibration
Note: The load must be applied before entering this
screen.
Adjust this reading to correspond with the known load
that is applied to the system.
For Low Amp Cal, the known load must be in the range
+/- 0-50A. For High Amp Cal the known load must be
within the range +/- 50-450A.
Note: You only need to do one range of calibration.
Up/Dn to select value.
Range: +/-450A (Max)
Refer to page 9
Reset Capacity
NO
YES
Refer to page 12