Use Up (V) / Down (A) buttons to change value then press C to proceed to the next set up
screen.
Set Alarm
Enable/Disable all alarms
Default: Enabled
Battery 1 label
Label battery bank 1 options are
House Batt, House 1, House 2,
Start Batt, Stbd Start, Port Start,
Aux Batt, Radio, Genset
Battery 2 label
As per Battery 1 label
Battery 3 label
As per Battery 1 label except includes
“Bilge monitor”
Refer to page 9
High voltage 1 alarm
Default: 15.0 Volts
Up/Dn to select value, 0.1V steps
Range: 10.0-32.0 Volts
Low voltage 1 alarm
Default: 11.0 Volts
Up/Dn to select value, 0.1V steps
Range: 0.0-32.0 Volts
High voltage 2 alarm
As per High voltage 1
Low voltage 2 alarm
As per Low voltage 1
High voltage 3 alarm
As per High voltage 1
Low voltage 3 alarm
As per Low voltage 1