ATIS TOP - Fancier
SUB-MENU CHECK
70
HB_TOP_ZUECHTER-E_22.doc
Gantner Pigeon Systems GmbH
With the function key
quit
you get back to the previous display.
Error:
If no loft antenna could be found you`ll hear a short beep and the following display
will appear:
Attention:
If no antenna is connected or found no pigeons resp. chip code rings can be
registered!
In that case the following checks are absolutely to be carried out:
1) Cabling:
between ATIS-Top and T-adaptor (CNN, ANN, INN)
2) Cabling:
between T-adaptor and distribution box DNN (if there is one) and
the loft-antennae
3) Plug connections:
are all connectors tightly and correctly joined (engaged)?
4) Supply voltage:
the green LED of the adaptor must be illuminated
5) Data communications: during the test, as long as the row of points in the bottom line of
the display is increasing, the yellow LED of the T-adaptor must
be flashing
If, however, an antenna error is still indicated in spite of these measures the only thing to
do is probably to disconnect (unplug) individually single antennae and cables. After each
disconnection, however, you should check again in order to find out the faulty part. In case
this proceeding shouldn`t lead to a satisfying result either, please contact your ATIS-
customer service.
* * a n t e n n a t e s t * *
N O A N T E N N A
Содержание ATIS TOP
Страница 1: ...ATIS TOP F A N C I E R U S E R M A N U A L V E R S I O N 2 2 0 ...
Страница 2: ......
Страница 4: ...2 HB_TOP_ZUECHTER E_22 doc Gantner Pigeon Systems GmbH ...
Страница 8: ...ATIS TOP Fancier TABLE OF CONTENTS 6 HB_TOP_ZUECHTER E_22 doc Gantner Pigeon Systems GmbH ...
Страница 99: ......